OSHA Inspection: P&R ROOFING AND REMODELING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of P&R ROOFING AND REMODELING, LLC in 5330 S. MILFORD RD., MILFORD, OH 45150 (NAICS 238160). OSHA activity number 345420756.

Watch P&R Roofing AND Remodeling, LLC — free Get an email when a new federal OSHA severe-injury report for P&R Roofing AND Remodeling, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5330 S. MILFORD RD.
City
MILFORD
State
OH
ZIP
45150
Mailing
2109 PITTSFIELD STREET, DAYTON, OH 45429
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4096.00 · Current $2000.00 Reduced
29 CFR  1926.501(b)(11):"Steep roofs." Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems.  On July 15, 2021, located on top of a cupola on building 317 of job-site address 5330 S. Milford Rd. Milford, OH 45150,  employees were exposed to a fall hazard while installing shingles onto a steep cupola roof not utilizing any fall protection system. Potential fall height measured 12'-6 with a roof pitch of 10 in 12.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4096

1926.502 A02

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4096.00 · Current $2000.00 Reduced
29 CFR 1926.502(a)(2): Employers shall provide and install all fall protection systems required by this subpart for an employee, and shall comply with all other pertinent requirements of this subpart before that employee begins the work that necessitates the fall protection. (A) Guardrail systems;  (B) Safety net systems; or  (C) Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems.  On July 15, 2021, located on top of a cupola on building 317 of job-site address 5330 S. Milford Rd. Milford, OH 45150, employees were exposed to a fall hazard while installing shingles on a steep cupola roof not utilizing any fall protection system in that the employer failed to install a fall protection system prior to the employees performing the work. Potential fall height measured 12'-6" with a roof pitch of 10 in 12.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4096