MILFORD, OH —
OSHA Inspection: P&R ROOFING AND REMODELING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of P&R ROOFING AND REMODELING, LLC in 5330 S. MILFORD RD., MILFORD, OH 45150 (NAICS 238160). OSHA activity number 345420756.
Where did this inspection happen?
- Establishment
- P&R ROOFING AND REMODELING, LLC
- Site address
- 5330 S. MILFORD RD.
- City
- MILFORD
- State
- OH
- ZIP
- 45150
- Mailing
- 2109 PITTSFIELD STREET, DAYTON, OH 45429
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B11
- Issued
- Penalty
- Initial $4096.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11):"Steep roofs." Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems. On July 15, 2021, located on top of a cupola on building 317 of job-site address 5330 S. Milford Rd. Milford, OH 45150, employees were exposed to a fall hazard while installing shingles onto a steep cupola roof not utilizing any fall protection system. Potential fall height measured 12'-6 with a roof pitch of 10 in 12.
Recent events (2)
- — I (S) $2000
- — Z (S) $4096
1926.502 A02
- Issued
- Penalty
- Initial $4096.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.502(a)(2): Employers shall provide and install all fall protection systems required by this subpart for an employee, and shall comply with all other pertinent requirements of this subpart before that employee begins the work that necessitates the fall protection. (A) Guardrail systems; (B) Safety net systems; or (C) Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems. On July 15, 2021, located on top of a cupola on building 317 of job-site address 5330 S. Milford Rd. Milford, OH 45150, employees were exposed to a fall hazard while installing shingles on a steep cupola roof not utilizing any fall protection system in that the employer failed to install a fall protection system prior to the employees performing the work. Potential fall height measured 12'-6" with a roof pitch of 10 in 12.
Recent events (2)
- — I (S) $2000
- — Z (S) $4096
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345420756.