1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: WIELAND THERMAL SOLUTIONS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WIELAND THERMAL SOLUTIONS, INC. in 707 NORTHGATE PARKWAY, WHEELING, IL 60090 (NAICS 331420). OSHA activity number 345446140.

Watch Wieland Thermal Solutions, INC. — free Get an email when a new federal OSHA severe-injury report for Wieland Thermal Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
707 NORTHGATE PARKWAY
City
WHEELING
State
IL
ZIP
60090
Mailing
567 NORTHGATE PARKWAY, WHEELING, IL 60090
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331420
Employees
80
Ownership type
A

2 citations on file for this inspection.

1910.147 D

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7802.00 · Current $5000.00 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) was not done in sequence to achieve energy control by performing the following steps as required by 29 CFR 1910.147(d)(1)-(6): 1.	Turn off and shut down power to the machinery, 2.	Physically locate and operate energy-isolating devices in such a manner as to isolate the machine or equipment from the energy source(s), 3.	Affix lockout/tagout devices to each energy isolating device, 4.	Verify isolation and de-energization of machinery have been accomplished prior to starting the maintenance and/or servicing work:  a) Finishing Department- On or about July 26, 2021, employees were exposed to machine hazards associated with moving parts while performing maintenance and servicing tasks on Finishing Lines, such as changing saw blades. The employer did not implement energy control application steps as the machine was not shut down and deenergized to perform setup or adjustments [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving dissipation machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $5000
  • — C (S) $7802
  • — Z (S) $7802

1910.212 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $9753.00 · Current $5000.00 Reduced
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible:  a) Finishing Department- On or about July 21, 2021, the employer did not ensure that all guards on machines, such as Finishing Line 3, were affixed and/or secured in a manner that would prevent employees from having any part of their body a point of operation or moving part danger zone during the operating cycle. The gate guard for the point of operation in the Eddy Current area was not secured or interlocked to prevent employees from accessing the area during normal production.  No abatement certification or documentation is required for this item.
Recent events (3)
  • — F (S) $5000
  • — C (S) $9753
  • — Z (S) $9753

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345446140.