Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: THE SIDING GUYS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THE SIDING GUYS in LOT 4 & 5 ECHELON RIDGE LOW TIER, BOISE, ID 83714 (NAICS 238170). OSHA activity number 345457733.

Watch THE Siding Guys — free Get an email when a new federal OSHA severe-injury report for THE Siding Guys is published. One employer, no account, unsubscribe in one click.
Establishment
THE SIDING GUYS
Site address
LOT 4 & 5 ECHELON RIDGE LOW TIER
City
BOISE
State
ID
ZIP
83714
Mailing
11482 WEST WAGON FAST CT, BOISE, ID 83709
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
9
Ownership type
A

4 citations on file for this inspection.

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $2048.00 Reduced
29 CFR  1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface were not used:  a) North side of lot 4 & 5: On August 3, 2021; an employee climbed onto a permanent railing and then climbed up to the top, working level of a scaffold.  The top of the balcony railing was 23 feet high, while the top, working level of the scaffold was over 25 feet high.    Note) Certification and documentation of corrective action are required for this item.
Recent events (2)
  • — I (S) $2048
  • — Z (S) $4096

1926.451 G01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection:  a) East side of Lot 4 & 5:  On August 3, 2021 and at times prior thereto; employees performed soffit and fascia work from a scaffold system without fall protection.  Guardrails or other means of personal fall protection were not used, exposing the employees to falls ranging from 13 feet to over 25 feet to the ground below.    b) North side of Lot 4 & 5:  On August 3, 2021 and at times prior thereto; an employee performed soffit and fascia work from a scaffold plank located between the railings of two balconies without fall protection.  Guardrails or other means of personal fall protection were not used, exposing the employee to a 13.5 foot fall to the ground below.     Note) Certification and documentation of corrective actions are required for these items.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.454(a): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:  a) On August 3, 2021 and at times prior thereto; employees performed soffit and fascia activities from multiple scaffold systems without guardrails or other means of fall protection.  The scaffolds varied in height from 13 feet to over 25 feet high.  The employees did not have the knowledge to recognize the hazards or to take the actions needed to minimize these hazards.  Note) Certification and documentation of corrective action are required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2926.00 · Current $1463.00 Reduced
29 CFR  1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system:  a) Lot 4 & 5:  On August 3, 2021; an employee performing soffit and fascia work from a flat, 1 in 3 pitch, roof deck was not protected from falling 13 feet to the concrete below.    Note) Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $1463
  • — Z (S) $2926

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345457733.