Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STERLING EXCAVATION, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STERLING EXCAVATION, LLC in 18 CRESTWAY ROAD, EAST BOSTON, MA 02128 (NAICS 237110). OSHA activity number 345474860.

Watch Sterling Excavation, LLC — free Get an email when a new federal OSHA severe-injury report for Sterling Excavation, LLC is published. One employer, no account, unsubscribe in one click.
Site address
18 CRESTWAY ROAD
City
EAST BOSTON
State
MA
ZIP
02128
Mailing
33 OAK SQUARE AVE., BRIGHTON, MA 02135
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
14
Ownership type
A

8 citations on file for this inspection.

1926.100 B

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $14502.00 · Current $1450.00 Reduced
29 CFR  1926.100(b):  Helmets for the protection of employees against impact and penetration of falling and flying objects did not meet the specifications contained in American National Standards Institute Z89.1-1969, Safety Requirements for Industrial Head Protection.  Location: Worksite.  On or about August 13, 2021, an employee was exposed to potential head injuries while wearing a hardhat that did not meet the specifications contained in American National Standards Institute Z89.1-1969, where the hardhat support band had been cut or damaged.
Recent events (3)
  • — F (S) $1450.2
  • — C (S) $14502
  • — Z (S) $14502

1926.651 I01

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $14502.00 · Current $1450.00 Reduced
29 CFR  1926.651(i)(1): Where the stability of adjoining buildings, walls, or other structures was endangered by excavation operations, support systems such as shoring, bracing or underpinning was not provided to ensure the stability of such structures for the protection of employees.  Location: Worksite  Employees were exposed to struck-by and caught between hazards while working where support systems such as shoring, bracing or underpinning was not provided to ensure the stability of adjoining buildings or earthen walls.
Recent events (3)
  • — F (S) $1450.2
  • — C (S) $14502
  • — Z (S) $14502

1926.1203 A

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $14502.00 · Current $1450.00 Reduced
29 CFR  1926.1203(a): Before work begins, the employer did not ensure that a competent person identifies all confined spaces in which one or more of the employees are to enter and evaluates any permit required confined spaces.  Location: Worksite  The Employer did not ensure that a competent person identified the sewer line manhole adjacent to the excavation as a confined space through consideration and evaluation of the elements of the space in which employees are working and are exposed to a potentially hazardous  atmosphere.
Recent events (3)
  • — F (S) $1450.2
  • — C (S) $14502
  • — Z (S) $14502

1926.20 B02

Willful Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $145027.00 · Current $14503.00 Reduced
29 CFR  1926.20(b)(2):The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person.  Location: Worksite  Employees are being exposed to hazards associated with overhead dropped objects, caught between and struck-by equipment where the employer does not conduct regular and frequent inspections of the jobsite to identify and eliminate such hazards.    The employer routinely fails to initiate and maintain a safety program, which provides for frequent and regular inspections of jobsites as demonstrated on or about August 13, 2021, when employer did not inspect the worksite located at 18 Crestway Road in order to identify and eliminated hazards.
Recent events (3)
  • — F (W) $14502.7
  • — C (W) $145027
  • — Z (W) $145027

1926.21 B02

Willful Gravity 10 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $145027.00 · Current $14503.00 Reduced
29 CFR  1926.21(b)(2):  The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  Location: Worksite  Employees are not adequately trained to recognize and avoid hazards such as struck-by, caught-between, and improper use of personal protective equipment while working where the employer has not provided proper training in hazard recognition.    The employer routinely fails to provide adequate training and instruction to each employee in the recognition and avoidance of hazards as demonstrated on or about August 13, 2021, on the 18 Crestway Road worksite in order to recognize and avoid hazards and exposure to injuries
Recent events (3)
  • — F (W) $14502.7
  • — C (W) $145027
  • — Z (W) $145027

1926.651 J01

Willful Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $145027.00 · Current $14503.00 Reduced
29 CFR  1926.651(j)(1):  Adequate protection was not provided to protect employees from loose rock or soil that could pose a hazard by falling or rolling from an excavation face.   Location: Worksite  Employees are exposed to struck-by hazards while working in excavations where the employer does not provide adequate protection from loose rock or soil that could pose a hazard by falling or rolling from an excavation face.  The employer routinely fails to provide protection for employees engaged in excavation work as demonstrated on August 13, 2021, at the 18 Crestway Road worksite where employees were exposed to excavation hazard injuries.
Recent events (3)
  • — F (W) $14502.7
  • — C (W) $145027
  • — Z (W) $145027

1926.652 A01

Willful Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $145027.00 · Current $14503.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).  Location: Worksite  Employees are being exposed to struck-by, caught between, and other hazards associated with excavations while working in foundation excavation with straight cut earthen walls, by not providing adequate protective systems designed in accordance with 29 CFR 1926.652 (b) or (c).  The employer routinely fails to provide protection for employees engaged in excavation work as demonstrated on August 13, 2021, at the 18 Crestway Road worksite where employees were exposed to excavation hazard injuries
Recent events (3)
  • — F (W) $14502.7
  • — C (W) $145027
  • — Z (W) $145027

1926.150 C01 IV

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1163.00 · Current $116.00 Reduced
29 CFR  1926.150(c)(1)(iv):One or more fire extinguishers, rated not less than 2A, were not provided on each floor.  Location: Worksite  Employees were exposed to fire hazards while working on a construction site where a fire extinguisher had not been provided.
Recent events (3)
  • — F (O) $116.3
  • — C (O) $1163
  • — Z (O) $1163

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345474860.