Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KNIGHT BROADBAND LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of KNIGHT BROADBAND LLC in 2112 HYATT DRIVE AT JOPLIN AVE, PORT CHARLOTTE, FL 33948 (NAICS 238210). OSHA activity number 345525091.

Watch Knight Broadband LLC — free Get an email when a new federal OSHA severe-injury report for Knight Broadband LLC is published. One employer, no account, unsubscribe in one click.
Site address
2112 HYATT DRIVE AT JOPLIN AVE
City
PORT CHARLOTTE
State
FL
ZIP
33948
Mailing
14480 62ND STREET NORTH, CLEARWATER, FL 33760
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238210
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $14502.00 · Current $14502.00
29 CFR  1926.21(b)(2):The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  At the job site: On or about September 9, 2021, employees who were not qualified persons were exposed to electrocution hazards when they were not trained and familiar with work practices such as, but not limited to, casting techniques and procedures, safe work in proximity of energized 13.2kV overhead power lines and minimum approach distances.
Recent events (2)
  • — C (S) $14502
  • — Z (S) $14502

1926.416 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $14502.00 · Current $14502.00
29 CFR  1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  At the job site: On or about September 9, 2021, employees were exposed to electrocution hazards, in that employees were permitted to work in close proximity to an energized 13.2 kV overhead power line and the employer did not ensure that the employees were protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means.
Recent events (2)
  • — C (S) $14502
  • — Z (S) $14502

1926.416 A03

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $14502.00 · Current $14502.00
29 CFR  1926.416(a)(3):Employer did not post or maintain proper warning signs at locations where the performance of the work could bring a person, tool, or machine into physical or electrical contact with an energized electrical power circuit:  At the job site: On or about September 9, 2021, employees were exposed to electrocution hazards, in that the employer failed to post or maintain proper warning signs when employees were installing aerial fiber cable in close proximity to an energized 13.2 kV overhead power line.
Recent events (2)
  • — C (S) $14502
  • — Z (S) $14502

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345525091.