HIGBEE, MO —
OSHA Inspection: CARTHAGE SYSTEM GENETICS, LLC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of CARTHAGE SYSTEM GENETICS, LLC. in 2948 COUNTY ROAD 2425, HIGBEE, MO 65257 (NAICS 112210). OSHA activity number 345547764.
Where did this inspection happen?
- Establishment
- CARTHAGE SYSTEM GENETICS, LLC.
- Site address
- 2948 COUNTY ROAD 2425
- City
- HIGBEE
- State
- MO
- ZIP
- 65257
- Mailing
- PO BOX 220, CARTHAGE, IL 62321
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 112210
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $14502.00 · Current $10877.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazards that would necessitate the need for trained first aid providers: The employer is failing to provide employees with adequate emergency medical response associated with remote work locations. This was most recently documented on or about September 23, 2021, at a workplace located at 2948 County Road 2425, Higbee, Missouri. The employer failed to have a person adequately trained to render emergency medical response within 3-4 minutes after identifying the injured victim. METHODS OF FEASIBLE ABATEMENT INCLUDE BUT IS NOT LIMITED TO: i. Develop and implement written procedures on responding to an urgent/severe employee injury ii. Train the employees and staff on the procedures for responding to an urgent/severe employee injury. iii. Identify personnel to serve as first responders and ensure those personnel are trained in first-aid, CPR and how to use a defibrillator as well as any other critical first responder training specific to your industry. iv. Provide first responders with the equipment and materials to provide emergency medical treatment required until emergency rescue arrives. v. Ensure first responders are on site whenever employees are working.
Recent events (2)
- — I (S) $10876.5
- — Z (S) $14502
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $14502.00 · Current $10877.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): 29 CFR Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to shock and electrocution hazards: The employer is failing to protect employees from shock or electrocution hazards assoicated with unsafe work practices, damaged facility and equipment wiring in an agriculture facility. This was most recently documented on or about September 23, 2021, at a workplace located at 2948 County Road 2425, Higbee, Missouri. Where the employer had employees performing various agriculture tasks while exposed to electrical hazards. Instances of exposure include but are not limited to: (a). Employees are exposed to electrical shock and electrocution hazards while cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws. This was observed on the cord used to power the Aaladin power washer in that the cord had to be turned upside down and held up by the use of straps secured to the circuit breaker panel and the control panel. (b). Employees are exposed to electrical shock and electrocution hazards in that the employer is failing to have employees visually inspect the portable cord and plug connected equipment and flexible cord sets (extension cords) before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to the outer jacket or insulation) and for evidence of possible internal damage. The employer failed to ensure that the portable GFCI (attached to cords) were in proper working condition. (c). Employees are exposed to electrical shock and electrocution hazards in that the employer is failing to keep sufficient access and working space was not provided, and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. (d). Employees are exposed to electrical shock and electrocution hazards in that flexible cords and cables are being run through doorways, windows, or similar openings. (e). Employees are exposed to electrical shock and electrocution hazards in that the employer is failing to have the equipment listed or labeled equipment and was not installed and used in accordance with any instructions included in the listing or labeling. (f). Employees are exposed to electrical shock and electrocution hazards in that the employer is failing to close unused openings in cabinets, boxes, and fittings. METHODS OF FEASIBLE ABATEMENT INCLUDE BUT ARE NOT LIMITED TO: i. The employer shall configure outlets, or install plugs meeting manufacturer's specification, at the facility that will not cause the equipment plugs to have the improper strain on the cords. ii. The employer shall implement a program in which employees visually inspect all portable equipment for defects and shall test equipment prior to use of equipment. iii. The employer shall implement a program to ensure that equipment has adequate working space around all electric equipment and materials are not stored near the equipment which can cause electrocution or fire hazards. iv. The employer shall remove all flexible cords that are being run through doorways, windows, or similar openings. v. The employer shall ensure that all equipment, including breaker panels, are properly listed and labeled to ensure employee safety. vi. The employer shall ensure that there are no unused openings in all cabinets, boxes or fittings.
Recent events (2)
- — I (S) $10876.5
- — Z (S) $14502
More inspections in this industry (NAICS 112210)
AUSTIN, MN—2026-02-10
110708 - MHF OF FREEBORN COUNTY INC
AUSTIN, MN—2026-02-10
110703 - MHF OF FREEBORN COUNTY INC
HANCOCK, MN—2026-02-03
110661 - MOORE LEAN LLP
HANCOCK, MN—2026-02-03
110660 - MOORE LEAN LLP
CASSATT, SC—2026-01-22
77312 - PRESTAGE FARMS
More inspections in MO
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345547764.