Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PASCHAL HEATING & AIR CONDITIONING CO., INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of PASCHAL HEATING & AIR CONDITIONING CO., INC. in 5733 W HIGHWAY 10, HACKETT, AR 72937 (NAICS 238220). OSHA activity number 345570667.

Watch Paschal Heating & AIR Conditioning CO., INC. — free Get an email when a new federal OSHA severe-injury report for Paschal Heating & AIR Conditioning CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
5733 W HIGHWAY 10
City
HACKETT
State
AR
ZIP
72937
Mailing
280 N MAESTRI ROAD, TONTITOWN, AR 72770
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
169
Ownership type
A

3 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $13052.00 · Current $9789.00 Reduced
29 CFR  1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means.  On or about October 8, 2021, employees performing  work on electrical circuits were exposed to energized circuits in that, at all times during the installation, the circuit was not deenergized or guarded.
Recent events (2)
  • — I (S) $9789
  • — Z (S) $13052

1926.417 B

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.417(b): Equipment or circuits that were de-energized did not have tags attached at all points where such equipment or circuits could be energized.   On or about October 8, 2021, employees performing electrical wire installment for a water heater were exposed to energized circuits in that, circuits to be de-energized were not tagged.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.39 A01

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $9324.00 · Current $6993.00 Reduced
29 CFR  1904.39(a)(1):The employer did not report within 8-hours the death of an employee resulting from a work-related incident.  On or about October 8, 2021, the employer did not report an employee death within 8-hours.
Recent events (2)
  • — I (O) $6993
  • — Z (O) $9324

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345570667.