ROCHESTER, NY —
OSHA Inspection: ROCHESTER GAS AND ELECTRIC CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ROCHESTER GAS AND ELECTRIC CORPORATION in 1099 EAST MAIN STREET, ROCHESTER, NY 14609 (NAICS 221122). OSHA activity number 345595060.
Where did this inspection happen?
- Establishment
- ROCHESTER GAS AND ELECTRIC CORPORATION
- Site address
- 1099 EAST MAIN STREET
- City
- ROCHESTER
- State
- NY
- ZIP
- 14609
- Mailing
- 1300 SCOTTSVILLE RD, ROCHESTER, NY 14624
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221122
- Employees
- 100
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.1200 H03 III
- Issued
- Abate by
- Penalty
- Initial $6215.00 · Current $6215.00
General-duty citation text
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used: (Construction Reference: 1926.59) a) On or about 10/11/2021, at a road construction project located near 1099 East Main Street, Rochester, New York; employees were repairing an 8" steel gas main that had been damaged by a contractor. During the repair work, an employee was using an abrasive wheel grinder to remove a damaged 2" service tee. The natural gas was still flowing at service pressure during the work and ignited as a result of the sparks from the grinder. Employees were not trained in specific procedures to monitor flammability limits, control ignition sources or appropriate product control measures when performing emergency repairs. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $6215
1926.24
- Issued
- Abate by
- Penalty
- Initial $6215.00 · Current $6215.00
General-duty citation text
29 CFR 1926.24:The employer shall be responsible for the development and maintenance of an effective fire protection and prevention program at the job site throughout all phases of the construction, repair, alteration, or demolition work: a) On or about 10/11/2021, at a road construction project located near 1099 East Main Street, Rochester, New York; employees were repairing an 8" steel gas main that had been damaged by a contractor. During the repair work, an employee was using an abrasive wheel grinder to remove a damaged 2" service tee. The natural gas was still flowing at service pressure during the work and ignited as a result of the sparks from the grinder. Methods to prevent the ignition of the natural gas were not followed and/or maintained. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $6215
1926.651 G01 III
- Issued
- Abate by
- Penalty
- Initial $6215.00 · Current $6215.00
General-duty citation text
29 CFR 1926.651(g)(1)(iii): Adequate precautions were not taken such as providing ventilation, to prevent employee exposure to an atmosphere containing a concentration of a flammable gas in excess of 20 percent of the lower flammable limit of the gas: a) On or about 10/11/2021, at a road construction project located near 1099 East Main Street, Rochester, New York; employees were repairing an 8" steel gas main that had been damaged by a contractor. During the repair work, an employee was using an abrasive wheel grinder to remove a damaged 2" service tee. The natural gas was still flowing at service pressure during the work and ignited as a result of the sparks from the grinder. There was no air monitoring performed to verify natural gas concentration or confirm flammable limits. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $6215
More inspections in this industry (NAICS 221122)
MONROE, GA—2026-07-14
WALTON EMC
DETROIT, MI—2026-07-14
EES COKE BATTERY, LLC
LITTLETON, MA—2026-07-01
LITTLETON ELECTRIC LIGHT & WATER DEPARTMENT
PISCATAWAY, NJ—2026-06-30
PSE&G
BAYTOWN, TX—2026-06-30
CENTERPOINT ENERGY
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345595060.