Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BYERLY GROUP I, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BYERLY GROUP I, INC. in 1111 SOUTHGATE DRIVE, WINDSOR, CO 80550 (NAICS 423110). OSHA activity number 345603005.

Watch Byerly Group I, INC. — free Get an email when a new federal OSHA severe-injury report for Byerly Group I, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1111 SOUTHGATE DRIVE
City
WINDSOR
State
CO
ZIP
80550
Mailing
1111 SOUTHGATE DRIVE, WINDSOR, CO 80550
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423110
Employees
16
Ownership type
A

7 citations on file for this inspection.

1910.151 C

Serious Gravity 1 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $2486.00 · Current $1875.00 Reduced
29 CFR  1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   29 CFR  1910.178(a)(3): Approved trucks did not bear a label or some other identifying mark indicating approval by the testing laboratory.    (a) Byerly Group I, Inc., DBA  HWY 34 RV, 1111 Southgate Dr., Windsor, CO 80550: On or before October 27, 2021, the eye wash stations at the facility do not have adequate water flow.  Abatement Note: ANSI Z358.1-2009 specifies that eye wash stations shall have 15 minutes of continuous flow.
Recent events (2)
  • — I (S) $1875
  • — Z (S) $2486

1910.178 A03

Serious Gravity 1 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $2486.00 · Current $1875.00 Reduced
29 CFR  1910.178(a)(3): Approved trucks did not bear a label or some other identifying mark indicating approval by the testing laboratory.    (a) Byerly Group I, Inc., DBA  HWY 34 RV, 1111 Southgate Dr., Windsor, CO 80550: On or before October 27, 2021, there was not an identifying label on a Toyota fork lift that was being used by the employer.
Recent events (2)
  • — I (S) $1875
  • — Z (S) $2486

1910.178 L01 I

Serious Gravity 5 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).  (a) Byerly Group I, Inc., DBA  HWY 34 RV, 1111 Southgate Dr., Windsor, CO 80550: On or before October 27, 2021, the employer did not ensure that the employees were trained in the safe operation of powered industrial trucks. This condition exposed employees to struck by-hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $3315.00 · Current $1875.00 Reduced
29 CFR  1910.1200(e)(1): The employer did not develop, implement, and maintain at each workplace, a written hazard communication program which described how the criteria specified in 29 CFR 1910.1200 paragraphs (f), (g), and (h) for labels and other forms of warning, safety data sheets, and employee information and training would be met.  (a) Byerly Group I, Inc,. DBA  HWY 34 RV, 1111 Southgate Dr., Windsor, CO 80550: On or before October 27, 2021, the employer did not have a written hazard communication program. This condition exposed employees to chemical hazards including, but not limited to exposure to:  1. Zep Super Flash, 2. Zep Cherry Bomb,  3. Zep Grip, and  4. Insight II.
Recent events (2)
  • — I (S) $1875
  • — Z (S) $3315

1910.1200 G08

Serious Gravity 1 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(g)(8):  The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical:  (a) Byerly Group I, Inc., DBA  HWY 34 RV, 1111 Southgate Dr., Windsor, CO 80550:: On or before October 27, 2021, the employer did not maintain safety data sheets onsite.  This condition exposes employees to chemical hazards including, but not limited to exposure to:  1. Zep Super Flash, 2. Zep Cherry Bomb,  3. Zep Grip, and  4. Insight II.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $3315.00 · Current $1875.00 Reduced
29 CFR  1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:   (a) Byerly Group I, Inc., DBA  HWY 34 RV, 1111 Southgate Dr., Windsor, CO 80550:On or before October 27, 2021, the employer did not adequately train employees on their hazard communication program. This condition exposes employees to chemical hazards including, but not limited to exposure to:  1. Zep Super Flash, 2. Zep Cherry Bomb,  3. Zep Grip, and  4. Insight II.
Recent events (2)
  • — I (S) $1875
  • — Z (S) $3315

1910.303 B01

Other-than-serious 2 instances 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1):   (a) Byerly Group I, Inc., DBA  HWY 34 RV, 1111 Southgate Dr., Windsor, CO 80550: On or before October 27, 2021, the employer did not ensure that a power cord  to power RVs and/or trailers while being serviced was not fully covered. The sheathing on a cord in the main bay area was pulled away from the plug. This condition potentially exposed employees to electrical shock hazards.  (b) Byerly Group 1 Inc, DBA  HWY 34 RV, 1115 Southgate Dr., Windsor, CO 80050: On or before October 27, 2021, the employer did not ensure that a power cord used to power RVs and/or trailers while being serviced was not fully covered. The sheathing on a cord  in the storage area was pulled away from the plug. This condition potentially exposed employees to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

COPART

COPART

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345603005.