OSHA Inspection: BYRON LEONEL ARANA VARELA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BYRON LEONEL ARANA VARELA in 3955 EBRINGTON ROAD, NEW ALBANY, OH 43054 (NAICS 238140). OSHA activity number 345661011.

Watch Byron Leonel Arana Varela — free Get an email when a new federal OSHA severe-injury report for Byron Leonel Arana Varela is published. One employer, no account, unsubscribe in one click.
Site address
3955 EBRINGTON ROAD
City
NEW ALBANY
State
OH
ZIP
43054
Mailing
1674 BURLINGTON AVE., COLUMBUS, OH 43227
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2926.00 · Current $2926.00
29 CFR  1926.451(b)(1):Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)  a) BYRON LEONEL ARANA VARELA located at 3955 Ebrington Road, New Albany, OH 43054:  On and preceding December 1, 2021, the employer did not ensure that each platform on all working levels of scaffolds were fully planked or decked between the front uprights and the guardrail supports. The following condition exposed employees to falls in excess of 16 feet.
Recent events (1)
  • — Z (S) $2926

1926.451 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2926.00 · Current $2926.00
29 CFR  1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates and mud sills or other adequate firm foundation:  a) BYRON LEONEL ARANA VARELA located at 3955 Ebrington Road, New Albany, OH 43054:  On and preceding December 1, 2021, a supported  scaffold that was in use did not bear an adequate firm foundation.  A two tier supported scaffold positioned at the back of a home was being utilized by masonry workers which was not resting on a stable foundation. The following condition exposed employees to falls in excess of 16 feet and struck-by hazards should the scaffolding collapse.
Recent events (1)
  • — Z (S) $2926

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2926.00 · Current $2926.00
29 CFR  1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used.   a) BYRON LEONEL ARANA VARELA located at 3955 Ebrington Road, New Albany, OH 43054:  On and preceding December 1, 2021, a supported  scaffold that was in use did not have an adequate means for access in place which led to masons using the scaffolding structure to climb the side of the scaffold to access the upper level.  The following condition exposed employees to falls in excess of 16 feet while transitioning from the side structure to the platform.
Recent events (1)
  • — Z (S) $2926

1926.451 F03

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $4096.00
29 CFR  1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:   a) BYRON LEONEL ARANA VARELA located at 3955 Ebrington Road, New Albany, OH 43054:  On and preceding December 1, 2021,  the employer did not ensure that scaffolds and scaffold components were inspected for correct installation by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. A two tier supported scaffold positioned at the back of a home was being utilized by masonry workers which had visible deflects including but not limited to missing guardrails, missing planking and missing crossbracing which was not identified and corrected before the scaffold was utilized. The following condition exposed employees to falls in excess of 16 feet and struck-by hazards should the scaffolding collapse.
Recent events (1)
  • — Z (S) $4096

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $4096.00
29 CFR  1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level.   a) BYRON LEONEL ARANA VARELA located at 3955 Ebrington Road, New Albany, OH 43054:  On and preceding December 1, 2021,  the employer did not ensure that employees on scaffolds more than 10 feet above a lower level were protected from falls. Masonry workers were positioned on the second level of a two tier scaffold, approximately 16 feet high installing brick and other masonry pieces. The second tier and other sections of the scaffolding did not have guardrails or other means of fall protection installed which exposed employees to falls in excess of 16 feet.
Recent events (1)
  • — Z (S) $4096