KENOSHA, WI —
OSHA Inspection: DICK'S ROOF REPAIR SERVICE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DICK'S ROOF REPAIR SERVICE, INC. in 4416 TAFT RD., KENOSHA, WI 53143 (NAICS 238160). OSHA activity number 345661870.
Where did this inspection happen?
- Establishment
- DICK'S ROOF REPAIR SERVICE, INC.
- Site address
- 4416 TAFT RD.
- City
- KENOSHA
- State
- WI
- ZIP
- 53143
- Mailing
- 3008 75TH STREET, KENOSHA, WI 53142
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $3170.00 · Current $1250.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or about December 1, 2021, employee(s) conducting roofing work on a 4:12 pitch roof on the west side of the detached garage structure, were not protected from falling to the lower level. This exposed employees to a fall hazard of approximately eight (8) feet four (4) inches. (b) On or about December 1, 2021, employees conducting roofing repair work on a 10:12 pitch roof on the west side of the main house structure, were not protected from falling to the lower level. This exposed employees to a fall hazard of approximately nine (9) feet four (4) inches at the eave.
Recent events (2)
- — I (S) $1250
- — Z (S) $3170
1926.1053 B04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) West side of detached garage: On or about December 1, 2021, an employee engaged in roofing work on the West side of detached garage, was using a Werner eight (8) foot step ladder designed to be used in the open, and braced/ locked position, while the ladder was left in the closed position and leaned against the structure. The employee used the first two steps of the ladder for elevation to perform work.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at DICK'S ROOF REPAIR SERVICE, INC.
KENOSHA, WI—2010-03-25 00:00:00
DICK'S ROOF REPAIR SERVICE, INC.
KENOSHA, WI—2009-04-17 00:00:00
DICK'S ROOF REPAIR SERVICE, INC.
KENOSHA, WI—2008-04-04 00:00:00
DICK'S ROOF REPAIR SERVICE, INC.
View DICK'S ROOF REPAIR SERVICE, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345661870.