1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: DOVAL CONSTRUCTION INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of DOVAL CONSTRUCTION INC. in 401 K STREET NE, WASHINGTON, DC 20002 (NAICS 238140). OSHA activity number 345696488.

Watch Doval Construction INC. — free Get an email when a new federal OSHA severe-injury report for Doval Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
401 K STREET NE
City
WASHINGTON
State
DC
ZIP
20002
Mailing
3708 BUNKER HILL RS APT 1A, BRENTWOOD, MD 20722
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3698.00 · Current $3698.00
29 CFR  1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a) On or about December 20, 2021; west side and rear area of residential site; employees working near the scaffold system were not wearing hard hat to protect them from falling objects such as but not limited to tools or materials used in the process.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3698

1926.451 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3698.00 · Current $3698.00
29 CFR  1926.451(b)(1):Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights   a) On or about December 20, 2021; West-side and rear area of the residential site; the cross-over platforms of the scaffold system were not fully planked exposing the employees to an estimated 25-foot fall hazard while conducting masonry or traveling between scaffolds.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3698

1926.451 G01 VII

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  a) On or about December 20, 2021; West-side and rear area of the residential project; employees conducting masonry work were exposed to an estimated 25-foot fall while walking across an unguarded cross-over which united the scaffolds and while working on the scaffold system.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.451 G04 I

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:  a) On or about December 20, 2021; side and rear area of residential project; the working platforms of the scaffold system was not guarded by railing at its ends to prevent employees from falling an estimated 25-feet to ground level while conducting masonry work.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.451 G04 III

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.451(g)(4)(iii): When midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent structural members are used, they were not installed between the top edge of the guardrail system and the scaffold platform.  a) On or about December 20, 2021; West-side and rear of the residential site; the employer had not installed mid-rails along the working platforms exposing the employees to an estimated 25-foot fall hazard while hoisting materials to the platform.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.451 H02 II

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.451(h)(2)(ii):A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below:  a) On or about December 20, 2021; west-side and rear of the residential home; working platforms of the scaffold system had no toe-boards to prevent masonry tools or materials from falling and striking the employee working at the ground.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

View DOVAL CONSTRUCTION INC.'s full OSHA safety record →