Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUPERIOR WATERPROOFING CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUPERIOR WATERPROOFING CO., INC. in 11900 BROADWAY ST., PEARLAND, TX 77588 (NAICS 238140). OSHA activity number 345702336.

Watch Superior Waterproofing CO., INC. — free Get an email when a new federal OSHA severe-injury report for Superior Waterproofing CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
11900 BROADWAY ST.
City
PEARLAND
State
TX
ZIP
77588
Mailing
9334 TALTON ST., HOUSTON, TX 77078
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
8
Ownership type
A

3 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $3901.00 · Current $3901.00
29 CFR  1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used.  a) On or about December 27, 2021, on the side of a building, employees were not provided a ladder to access platforms on a scaffold, exposing them to fall hazards.
Recent events (1)
  • — Z (S) $3901

1926.451 G01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $3901.00 · Current $3901.00
29 CFR  1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  (a) On or about December 27, 2021, on the side of the building, where employees were exposed to a fall hazard greater than 10 feet while applying stucco on a wall from a scaffold without a fall protection system.
Recent events (1)
  • — Z (S) $3901

1926.452 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $3901.00 · Current $3901.00
29 CFR  1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or a combination thereof, which secure vertical members together laterally:  a) On or about December 27, 2021, on the east side of a building, where employees were exposed to a fall hazard while applying stucco onto a wall from a scaffold without interior cross braces.
Recent events (1)
  • — Z (S) $3901

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345702336.