GRAND JUNCTION, CO —
OSHA Inspection: TRENT SPENDRUP CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TRENT SPENDRUP CORPORATION in 2768 C 1/2 ROAD, GRAND JUNCTION, CO 81502 (NAICS 333413). OSHA activity number 345759567.
Where did this inspection happen?
- Establishment
- TRENT SPENDRUP CORPORATION
- Site address
- 2768 C 1/2 ROAD
- City
- GRAND JUNCTION
- State
- CO
- ZIP
- 81502
- Mailing
- P.O. BOX 4308, GRAND JUNCTION, CO 81502
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333413
- Employees
- 45
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $10151.00 · Current $6000.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines, whose operation exposes an employee to injury, were not guarded: a. Trent Spendrup Corporation DBA Spendrup Fan Company, Inc. at 2768 C 1/2 Rd, Grand Junction, CO 81501: On and before January 31, 2022, the employer did not protect employees from hazards by ingoing nip points. On January 19, 2022 one employee was injured after being directed to use the Roundo Section Bending Machine without the use of machine guards or other means to keep workers away from the point of operation. This condition exposed employees to crushing hazards.
Recent events (2)
- — I (S) $6000
- — Z (S) $10151
1910.303 G02 I
- Issued
- Abate by
- Penalty
- Initial $8702.00 · Current $4000.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Exposed live electrical parts were not protected from accidental contact by an approved enclosure: a. Trent Spendrup Corporation DBA Spendrup Fan Company, Inc. at 2768 C 1/2 Rd, Grand Junction, CO 81501: On or about January 31, 2022, the employer did not protect employees from electrical hazards while operating the machine. It was observed that the backside panel of the Roundo Section Bending Machine was not covered. The opening was large enough for arms and legs to enter and contact live electrical conductors. Employees are in this area when replacing the machine cover after use because the covers are set behind the machine during use. Employees were exposed to shock, electrocution and burn hazards.
Recent events (2)
- — I (S) $4000
- — Z (S) $8702
More inspections in this industry (NAICS 333413)
MESA, AZ—2026-06-19
CPX2026XBM831X0026 - CHILLER CITY CORPORATION
ATLANTA, GA—2026-06-04
OSPREY CORPORATION
MIAMI, FL—2026-05-28
FILTER KING, LLC
JACKSONVILLE, FL—2026-05-27
THE SY-KLONE COMPANY, LLC
FARMINGTON, CT—2026-05-27
EBM-PAPST INC.
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345759567.