Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MEMORIAL MONUMENTS & VAULTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MEMORIAL MONUMENTS & VAULTS, INC. in 300 MANDAN AVENUE, MANDAN, ND 58554 (NAICS 327390). OSHA activity number 345768949.

Watch Memorial Monuments & Vaults, INC. — free Get an email when a new federal OSHA severe-injury report for Memorial Monuments & Vaults, INC. is published. One employer, no account, unsubscribe in one click.
Site address
300 MANDAN AVENUE
City
MANDAN
State
ND
ZIP
58554
Mailing
598 WEST FRANKLIN ROAD, MERIDIAN, ID 83642
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
7
Ownership type
A

10 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $13052.00 · Current $0.00 Reduced
OSH ACT of 1970 Section (5)(a)(1):Section 5(a)(1) of the Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were not protected from crushing/struck-by hazards:  (a)	On February 8, 2022 and times prior, at or near 300 Mandan Avenue in Mandan, North Dakota, for the employee exposed to crushing/struck-by hazards while conducting lifting operations utilizing an overhead gantry crane where the under the hook lifting devices manufactured in house, were not inspected or tested to determine the weight rating.  Note: Among other methods, one feasible and accepted method to correct this hazard would be to follow the requirements contained within ANSI ANSI/ASME B30.20 Below the hook lifting devices; to ensure that all devices attached to the hook of the gantry cranes are fabricated, inspected and tested to determine the devices weight rating.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13052

1910.106 E02 II B

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $13052.00 · Current $10000.00 Reduced
29 CFR  1910.106(e)(2)(ii)(b): The quantity of liquid that may be located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building shall not exceed:  (1)  25 gallons of Category 1 flammable liquids in containers (2)  120 gallons of Category 2, 3, or 4 flammable liquids in containers (3)  660 gallons of Category 2, 3, or 4 flammable liquids in a single portable tank.  (a)	On February 8, 2022 and times prior, at or near 300 Mandan Avenue in Mandan, North Dakota, for the employee exposed to fire hazards where flammable liquids exceeding acceptable quantity limits, are stored in cabinets not meeting the requirements to be classified as flammable liquid storage. -
Recent events (2)
  • — I (S) $10000
  • — Z (S) $13052

1910.179 J03

Serious Gravity 10 2 instances 4 exposed
Issued
Penalty
Initial $13052.00 · Current $10000.00 Reduced
29 CFR  1910.179(j)(3):Complete inspections of the crane was not being performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section:  (a)	On February 8, 2022 and times prior, at or near 300 Mandan Avenue in Mandan, North Dakota, for the employee exposed to crushing hazards where overhead gantry cranes utilized for lifting operations were not inspected periodically by a person meeting the definition of a competent person to ensure the safe operation of the cranes.
Recent events (2)
  • — I (S) $10000
  • — Z (S) $13052

1910.184 C01

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.184(c)(1):Sling(s) that were damaged or defective were used:  (a)	On February 8, 2022 and times prior, at or near 300 Mandan Avenue in Mandan, North Dakota, for the employee exposed to crushing hazards where synthetic web sling used to lift the concrete hopper and the quad leg lifting device did not have the required safety latch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.184 F05 I

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.184(f)(5)(i):Wire rope sling(s) that had ten or more randomly distributed broken wires in one rope lay, or five or more broken wires in one strand in one rope lay, were not immediately removed from service:  (a)	On February 8, 2022 and times prior, at or near 300 Mandan Avenue in Mandan, North Dakota, for the employee exposed to crushing hazards where wire rope lifting slings had more than the allowable broken wire strands in one rope lay.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.243 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1047.00 · Current $418.00 Reduced
29 CFR  1910.243(c)(1):Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4)of this section:  (a)	On February 8, 2022 and times prior, at or near 300 Mandan Avenue in Mandan, North Dakota, for the employee exposed to injury from flying debris where a Milwaukee angle grinder did not have the required guard attached.
Recent events (2)
  • — I (O) $418
  • — Z (O) $1047

1910.254 D09 III

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1047.00 · Current $418.00 Reduced
29 CFR  1910.254(d)(9)(iii):Cables with damaged insulation or exposed bare conductors were not replaced:  (a)	On February 8, 2022 and times prior, at or near 300 Mandan Avenue in Mandan, North Dakota, for the employee exposed to electrical shock hazards where the welder lead sheathing was split open near the welding gun handle.
Recent events (2)
  • — I (O) $418
  • — Z (O) $1047

1910.334 A02 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.334(a)(2)(ii):There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  (a)	On February 8, 2022 and times prior, at or near 300 Mandan Avenue in Mandan, North Dakota, for the employee exposed to electrical shock hazards where a plug and cord set that was damaged was not taken out of service.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1047.00 · Current $418.00 Reduced
29 CFR  1910.1200(g)(1):Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  (a)	On February 8, 2022 and times prior, at or near 300 Mandan Avenue in Mandan, North Dakota, for the employee exposed to chemical hazards where the employer did not provide the Safety Data Sheets which provides critical information for the safe handling and use of the chemicals at the facility.
Recent events (2)
  • — I (O) $418
  • — Z (O) $1047

1910.1200 H01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1047.00 · Current $418.00 Reduced
29 CFR  1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a)	On February 8, 2022 and times prior, at or near 300 Mandan Avenue in Mandan, North Dakota, for the employee exposed to chemical hazards where the employer failed to train employees of the hazards associated with the chemicals that they are required to handle and use in the performance of their job duties.
Recent events (2)
  • — I (O) $418
  • — Z (O) $1047

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345768949.