OSHA Inspection: SOUTH TEXAS PROJECT ELECTRIC NUCLEAR OPERATING COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SOUTH TEXAS PROJECT ELECTRIC NUCLEAR OPERATING COMPANY in 12090 FM521 P.O. BOX 289, WADSWORTH, TX 77483, BAY CITY, TX 77414 (NAICS 221113). OSHA activity number 345777791.

Watch South Texas Project Electric Nuclear Operating Company — free Get an email when a new federal OSHA severe-injury report for South Texas Project Electric Nuclear Operating Company is published. One employer, no account, unsubscribe in one click.
Site address
12090 FM521 P.O. BOX 289, WADSWORTH, TX 77483
City
BAY CITY
State
TX
ZIP
77414
Mailing
P.O. BOX 289, WADSWORTH, TX 77483
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221113
Employees
1150
Ownership type
A

3 citations on file for this inspection.

1910.146 D06

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $14502.00 · Current $0.00 Reduced
29 CFR  1910.146(d)(6): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not provide at least one attendant outside the permit space into which entry was authorized for the duration of entry operations:  On or about February 10, 2021, and times prior thereto, employer did not provide an attendant as employees  conducted fire watch duties and accessed cable area room 215D, via the hatch door on the floor in room 318. employee was doing the fire watch task and exposed to fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14502

1910.23 B13

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $14502.00 · Current $0.00 Reduced
29 CFR 1910.23(b)(13):The employer did not ensure that no employee carries any object or load that could cause the employee to lose balance and fall while climbing up or down the ladder.   On or about February 10, 2021, and times prior thereto, employees were exposed to a fall hazard while descending to a lower level and the holding hatch door open.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14502

1910.305 B02 I

Deleted Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(b)(2)(i):All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.   On or about February 10  , 2022 and times prior thereto, in office building,  employees were exposed to electrical hazards in the workplace when a cover on the electric outlet was inadequate.