WASHINGTON, DC —
OSHA Inspection: WANG X GROUP LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WANG X GROUP LLC in 1509 D STREET NE, WASHINGTON, DC 20002 (NAICS 236118). OSHA activity number 345784540.
Where did this inspection happen?
- Establishment
- WANG X GROUP LLC
- Site address
- 1509 D STREET NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20002
- Mailing
- 12304 AUTUMN TREE LANE, CLARKSVILLE, MD 21029
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.95 A
- Issued
- Abate by
- Penalty
- Initial $1585.00 · Current $1585.00
General-duty citation text
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition: a) On or about February 10, 2022; third floor; the employer did not provide employees with eye protection while operating portable equipment such as but not limited to pneumatic nail-guns while performing framing activity. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet)
Recent events (1)
- — Z (S) $1585
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $4351.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about February 10, 2022; third floor; employees that were performing framing activity were exposed to fall hazard of approximately 40-feet while working on the top plate and securing the walls. b) On or about February 10, 2022; second floor; employees that were working around the stairs were exposed to a fall hazard of approximately 10 feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet)
Recent events (1)
- — Z (S) $4351
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $1585.00 · Current $1585.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about February 10, 2022; Third-floor area; employees were using a Werner 6-foot ladder to access the walls in which the rail is 4 feet below the landing exposing them to a fall hazard while accessing or using the ladder. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet)
Recent events (1)
- — Z (S) $1585
1926.1053 B13
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step: a) On or about June 30, 2021; second floor; the Werner stepladder used to access the work area was 4-feet to short forcing the employees to use the top-step exposing them to a fall hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet)
Recent events (1)
- — Z (S) $0
1926.403 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: a) On or about February 10, 2022; First floor area; the extension cord used to provide power to the equipment used in the process was damaged exposing the inner insulated wires. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet)
Recent events (1)
- — Z (O) $0
1926.503 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(b)(1):The employer did not verify fall protection training by preparing a written certification record. a) On or about February 10, 2022, third floor area; the employer had not certify that employees had been provided with fall protection training where employees were performing framing activity and were exposed to fall hazards of approximately 40 feet. In accordance with 29 CFR 1903.19(d), abatement ce1tification is required for this violation (using the Certification of Corrective Action Worksheet)
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 236118)
BROOKLYN, NY—2026-07-15
MEGA GENERAL CONSTRUCTION NYC INC.
BROOKLYN, NY—2026-07-15
MEGA GENERAL CONSTRUCTION NYC INC.
SYRACUSE, NY—2026-07-14
EMPIRE BUILDERS OF CNY, INC.
RENTON, WA—2026-07-14
WA317992055 - JCC INVESTMENT GROUP LLC
RIVERTON, NJ—2026-07-14
JBF CONSTRUCTION LLC
More inspections in DC