DURANGO, CO —
OSHA Inspection: DURANGO MOTOR COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DURANGO MOTOR COMPANY in 1200 CARBON JUNCTION, DURANGO, CO 81301 (NAICS 441110). OSHA activity number 345789002.
Where did this inspection happen?
- Establishment
- DURANGO MOTOR COMPANY
- Site address
- 1200 CARBON JUNCTION
- City
- DURANGO
- State
- CO
- ZIP
- 81301
- Mailing
- 1200 CARBON JUNCTION, DURANGO, CO 81301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441110
- Employees
- 180
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.303 G01 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1)(ii):The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) Durango Motor Company: On or before 2/17/22 the employer did not ensure that panel L1C was clear of stored items within 30 inches of the face of the panel. This condition exposed employees to electric shock and fire hazards. (b) Durango Motor Company: On or before 2/17/22 the employer did not ensure that panel L1E was clear of stored items within 30 inches of the face of the panel. This condition exposed employees to electric shock and fire hazards. (c) Durango Motor Company: On or before 2/17/22 the employer did not ensure that panel H1E was clear of stored items within 30 inches of the face of the panel. This condition exposed employees to electric shock and fire hazards. Abatement Note: Abatement certification is not required for this item.
Recent events (1)
- — Z (O) $0
1910.1200 F06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: (a) Durango Motor Company: On or before 2/17/22 the employer did not ensure that secondary containers were labeled in accordance with this standard. In the wash bay, spray bottles of perma plate and glass cleaner were not labeled. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (1)
- — Z (O) $0
More inspections at DURANGO MOTOR COMPANY
DURANGO, CO—2013-07-30 00:00:00
DURANGO MOTOR COMPANY
View DURANGO MOTOR COMPANY's full OSHA safety record →
More inspections in this industry (NAICS 441110)
SAN ANTONIO, TX—2026-07-08
NORTH PARK TOYOTA OF SAN ANTONIO
BIRMINGHAM, MI—2026-06-29
SIGNATURE ASSOCIATES, LLC
SACRAMENTO, CA—2026-06-24
MAITA TOYOTA OF SACRAMENTO
PATEROS, WA—2026-06-22
WA317991601 - COLUMBIA RIVER AUTO SALES LLC
RAYMOND, WA—2026-06-18
WA317991734 - FIVE STAR DEALERSHIPS INC
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345789002.