2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: T & H GRINDING COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of T & H GRINDING COMPANY, INC. in 3600 PINEMONT DRIVE, HOUSTON, TX 77018 (NAICS 327910). OSHA activity number 345850465.

Watch T & H Grinding Company, INC. — free Get an email when a new federal OSHA severe-injury report for T & H Grinding Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3600 PINEMONT DRIVE
City
HOUSTON
State
TX
ZIP
77018
Mailing
3600 PINEMONT DRIVE, HOUSTON, TX 77018
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327910
Employees
11
Ownership type
A

3 citations on file for this inspection.

1910.133 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3315.00 · Current $3315.00
29 CFR  1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  On or about March 23, 2022, an employee was exposed to flying metal particles while operating the "Norton" (No serial number, identified as Grinder #2) outer-diameter (OD) grinder.
Recent events (1)
  • — Z (S) $3315

1910.303 G02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3315.00 · Current $3315.00
29 CFR  1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage.  On or about March 23, 2022, at the Landis OD grinder, an employee was exposed to an electrical hazard while using a 120v lamp that did not have a cover to protect he bulb.
Recent events (1)
  • — Z (S) $3315

1910.305 G01 IV

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(1)(iv): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  On or about March 23, 2022, in the shop area, employees were exposed to electrical hazards from extension cords being used as a substitute for the fixed wiring.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345850465.