Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JUAN SOTELO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JUAN SOTELO in 327 BAY CLIFF, PORT ARANSAS, TX 78373 (NAICS 238160). OSHA activity number 345868772.

Watch Juan Sotelo — free Get an email when a new federal OSHA severe-injury report for Juan Sotelo is published. One employer, no account, unsubscribe in one click.
Establishment
JUAN SOTELO
Site address
327 BAY CLIFF
City
PORT ARANSAS
State
TX
ZIP
78373
Mailing
4102 UP RIVER ROAD, CORPUS CHRISTI, TX 78404
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2113.00 · Current $2113.00
29 CFR  1926.501(b)(13): Each employee(s)engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   On or about March 30, 2022, at this worksite, employee engaged in construction activities on a roof greater in height than six (6) feet was not provided with fall protection.
Recent events (1)
  • — Z (S) $2113

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2113.00 · Current $2113.00
29 CFR  1926.1053(b)(1):Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9m) above the upper landing surface to which the ladder was used to gain access:  On or about March 30, 2022, at this worksite, employee engaged in roofing activities, utilized a ladder to access/egress the roof. The ladder did not extend at least three feet over the roof landing.
Recent events (1)
  • — Z (S) $2113

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.1053(b)(4):Ladders shall be used only for the purpose for which they were designed:  On or about March 30, 2022, the employer and employee were using a closed step ladder to access/egress a multi level roof.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345868772.