CHICAGO, IL —
OSHA Inspection: JCP CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JCP CONSTRUCTION, INC. in 9128 S. COMMERCIAL AVENUE, CHICAGO, IL 60617 (NAICS 238140). OSHA activity number 345897250.
Where did this inspection happen?
- Establishment
- JCP CONSTRUCTION, INC.
- Site address
- 9128 S. COMMERCIAL AVENUE
- City
- CHICAGO
- State
- IL
- ZIP
- 60617
- Mailing
- 6 FIR STREET, CARPENTERSVILLE, IL 60110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $4351.00
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) On or about April 12, 2022, at the above addressed jobsite, employees were conducting masonry operations from a tubular welded frame scaffold that was not fully planked. The employees were, thereby, exposed to falls of approximately nineteen (19) to twenty-eight (28) feet above ground.
Recent events (1)
- — Z (S) $4351
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $4351.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access: a) On or about April 12, 2022, at the above addressed jobsite, employees were not equipped with a ladder to provide a safe means of access and egress, thereby, exposing the employees to falls of approximately nineteen (19) to twenty-eight (28) feet above ground.
Recent events (1)
- — Z (S) $4351
1926.451 E09 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(e)(9)(iv): Cross braces on tubular welded frame scaffolds were used as a means of access or egress. a) On or about April 12, 2022, at the above addressed jobsite, employees were climbing and standing on the rails and cross braces of the scaffold to reach their work zone. The employees were, thereby, exposed to falls of approximately nineteen (19) to twenty-eight (28) feet above ground.
Recent events (1)
- — Z (S) $0
1926.451 G04 I
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $4351.00
General-duty citation text
29 CFR 1926.451(g)(4)(i):Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews. a) On or about April 12, 2022, at the above addressed jobsite, employees were performing masonry operations from a tubular welded frame scaffold that was not equipped with a complete guardrail system including, but not limited to, midrails and endrails. Employees were, thereby, exposed to falls of approximately nineteen (19) to twenty-eight (28) feet above ground.
Recent events (1)
- — Z (S) $4351
More inspections at JCP CONSTRUCTION, INC.
CABO ROJO, PR—2004-02-18 00:00:00
JCP CONSTRUCTION INC
MAYAGUEZ, PR—2003-08-28 00:00:00
JCP CONSTRUCTION INC
SABANA GRANDE, PR—2003-07-14 00:00:00
JCP CONSTRUCTION INC
MAYAGUEZ, PR—2003-07-07 00:00:00
JCP CONSTRUCTION INC
CABO ROJO, PR—2003-05-06 00:00:00
JCP CONSTRUCTION INC
View JCP CONSTRUCTION, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345897250.