Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JC COMPANY

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of JC COMPANY in 870 HARDING AVE SUITE B, NEWFIELD, NJ 08344 (NAICS 326199). OSHA activity number 345908065.

Watch JC Company — free Get an email when a new federal OSHA severe-injury report for JC Company is published. One employer, no account, unsubscribe in one click.
Establishment
JC COMPANY
Site address
870 HARDING AVE SUITE B
City
NEWFIELD
State
NJ
ZIP
08344
Mailing
870 HARDING HIGHWAY SUITE B, NEWFIELD, NJ 08344
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
326199
Employees
11
Ownership type
A

9 citations on file for this inspection.

1910.106 E06 I

Serious Gravity 10 2 instances 9 exposed
Issued
Abate by
Penalty
Initial $5801.00 · Current $3307.00 Reduced
29 CFR  1910.106(e)(6)(i):Adequate precautions were not taken to prevent the ignition of flammable vapors.  a) Back Spraying Building: On or about 4/20/2022 and thereafter, 55-gallon drums of products, including but not limited to Orca Composites Resin Solution, a Category 3 Flammable, were not grounded while in use for spray coating operations.   b) Back Spraying Building: On or about 4/20/2022 and thereafter, spraying coating equipment and hoses were not grounded while in use for spray coating operations using products including, but not limited to Orca Composites Resin Solution, a Category 3 Flammable.   NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — P (S) $3307
  • — I (S) $3307
  • — Z (S) $5801

1910.107 C02

Serious Gravity 10 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $5801.00 · Current $3307.00 Reduced
29 CFR  1910.107(c)(2): Open flame or spark producing equipment was within a spraying area and/or within 20 feet thereof, was not separated by a partition:  a) Back Spraying Building: On or about 7/28/2022, precautions were not taken to prevent Category 3 flammable products, including but not limited to, Orca Composites Resin Solution, from ignition sources including but not limited to, Ryobi Grinder Model AG454, Serial HR22145D003674.  NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — P (S) $3307
  • — I (S) $3307
  • — Z (S) $5801

1910.107 C05

Serious Gravity 10 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $5801.00 · Current $3307.00 Reduced
29 CFR  1910.107(c)(5): Electrical equipment in spraying areas whereon deposits of combustible residues may readily accumulate were not approved for locations containing both deposits of readily ignitable residue and explosive vapors:  a) Back Spraying Building: On or about 4/20/2022 and thereafter, electrical equipment, including but not limited to, outlets, light switches, extension cords, and open junction boxes, were coated with overspray from flammable paints and were not rated for the area.    NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (4)
  • — P (S) $3307
  • — P (S) $3307
  • — I (S) $3307

1910.107 C06

Serious Gravity 10 2 instances 9 exposed
Issued
Abate by
Penalty
Initial $5801.00 · Current $3307.00 Reduced
29 CFR  1910.107(c)(6):Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for  Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:  a) Back Spraying Building: On or about 7/28/2022, an extension cord attached to a three outlet extender that was hard wired into the conduit was exposed to spraying operations with products including but not limited to, Orca Composites Resin Solution, a Category 3 flammable.   b) Back Spraying Building: On or about 4/27/2022, exposed wiring for light switches, electrical panels, and uncovered outlets were exposed to spraying operations with products including but not limited to, Orca Composites Resin Solution, a Category 3 flammable.  NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (4)
  • — P (S) $3307
  • — P (S) $3307
  • — I (S) $3307

1910.107 G02

Serious Gravity 5 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $4144.00 · Current $2362.00 Reduced
29 CFR  1910.107(g)(2):All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:  a) Back Spraying Building: On or about 6/10/2022 and thereafter, spray areas were not kept free of accumulation of  residues from Category 3 Flammables, including but not limited to, Orca Composites Resin Solution.  NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — P (S) $2362
  • — I (S) $2362
  • — Z (S) $4144

1910.134 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3315.00 · Current $2048.00 Reduced
29 CFR  1910.134(c)(1):A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  a) Facility: On or about 4/20/2022, a worksite specific respiratory protection program was not established for employees, including but not limited to Painters, who were required to use 3M 6300 elastomeric half face respirators.   NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — P (S) $2048
  • — I (S) $2048
  • — Z (S) $3315

1910.134 E01

Serious Gravity 1 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) Facility: On or about 4/18/2022, employees required to wear 3M 6300 half face elastomeric respirators were not medically evaluated prior to wearing the respirators.  NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — P (S) $0
  • — I (S) $0
  • — Z (S) $0

1910.1200 G01

Serious Gravity 5 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $4144.00 · Current $2362.00 Reduced
29 CFR  1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use.  a) Facility: On or about 4/20/2022, Safety Data Sheets for chemicals used in the workplace including, but not limited to, Orca Composites Resin Solution, a Category 3 Flammable, and Orca Solutions MEKP, a corrosive, were not available.   NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — P (S) $2362
  • — I (S) $2362
  • — Z (S) $4144

1910.1200 E01 I

Other-than-serious 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(e)(1)(i):The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.  a) Facility: On or about 4/20/2022, the written Hazard Communication Plan did not include a list of hazard chemicals for the location including, but not limited to, Orca Composites Resin Solution, a Category 3 Flammable, and Orca Solutions Clear MEKP, a corrosive.  NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — P (O) $0
  • — I (O) $0
  • — Z (O) $0

JC COMPANY

View JC COMPANY's full OSHA safety record →