CALDWELL, ID —
OSHA Inspection: BZR POWER DIVISION LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of BZR POWER DIVISION LLC in 11105 LINDEN ROAD, CALDWELL, ID 83605 (NAICS 237130). OSHA activity number 345912760.
Where did this inspection happen?
- Establishment
- BZR POWER DIVISION LLC
- Site address
- 11105 LINDEN ROAD
- City
- CALDWELL
- State
- ID
- ZIP
- 83605
- Mailing
- 4777 S CREE WAY, BOISE, ID 83709
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237130
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury. a) On or prior to April 21, 2022; the employer did not instruct employees in trenching and excavation hazards including potential cave-in hazards prior to working in trenches and excavations. Employees were working to install two 6" conduits in a trench without cave-in protection. The trench measured approximately 4.0-6.0 feet deep, had nearly vertical walls and was Type B soil next to a previously installed utility line. Note - Abatement documentation and certification are required for this item
Recent events (2)
- — I (S) $0
- — Z (S) $4351
1926.651 C02
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees. a) On April 21, 2022; the employer did not ensure the use of an appropriate ladder or other safe means of egress while employees were working to install two 6" conduits in a trench at a depth ranging from 4.0-6.0 feet deep. Employees jumped in as ingress and/or utilized the side and the end of the trench as egress from the work location. Note: Abatement documentation and certification are required for this item.
Recent events (2)
- — I (S) $3500
- — Z (S) $4351
1926.651 K01
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. Inspections were not conducted by the competent person prior to the start of work and as needed throughout the shift. a) On April 21, 2022; the employer did not ensure a "competent person" inspected the trench for hazards prior to directing employees to enter the trench. Employees were working to install two 6" conduits in a trench measuring approximately 4.0-6.0 feet deep, with nearly vertical walls and Type B soil without any cave-in protection. This work was occurring directly adjacent and parallel to a previously installed utility line with unstable backfill around it. NOTE - Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $3500
- — Z (S) $4351
1926.652 A01
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation is not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section. a) On April 21, 2022; the employer did not protect employees working to install two 6" conduits in a trench without cave-in protection at a depth ranging from 4.0-6.0 feet with nearly vertical walls and Type B soil. This work was occurring directly adjacent and parallel to a previously installed utility line with unstable backfill around it. Note - Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $3500
- — Z (S) $4351
More inspections in this industry (NAICS 237130)
TWINSBURG, OH—2026-07-14
ERVIN CABLE CONSTRUCTION, LLC
LEXINGTON, KY—2026-07-09
69310 - DAVIS H ELLIOT COMPANY INC
POUGHQUAG, NY—2026-07-09
MK SHARP LLC.
KENMORE, WA—2026-07-08
WA317991980 - CASCADE TOWER & RIGGING INC
HUBBARD, TX—2026-07-07
3B DOZER SERVICE LLC
More inspections in ID
BOISE, ID—2026-07-16
RAYMOND MANAGEMENT COMPANY
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15
MIRZON CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15
EASTER SEALS - GOODWILL NORTHERN ROCKY MOUNTAINS
NAMPA, ID—2026-07-15
ELITE STEEL ERECTORS, LLC
Source