ATLANTA, GA —
OSHA Inspection: DIG ENTERPRISE LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DIG ENTERPRISE LLC in 2151 BOLTON ROAD NW, ATLANTA, GA 30311 (NAICS 237110). OSHA activity number 345917041.
Where did this inspection happen?
- Establishment
- DIG ENTERPRISE LLC
- Site address
- 2151 BOLTON ROAD NW
- City
- ATLANTA
- State
- GA
- ZIP
- 30311
- Mailing
- 4494 ACWORTH INDUSTRIAL DRIVE, NW 103, ACWORTH, GA 30101
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 12
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.602 A09 I
- Issued
- Penalty
- Initial $3315.00 · Current $1989.00 Reduced
General-duty citation text
29 CFR 1926.602(a)(9)(i):Bidirectional machine(s) were not equipped with an operable horn, distinguishable from the surrounding noise level, which could be operated as needed when the machine is moving in either direction. a) Bolton Road Apartments located at 2151 Bolton Road NW, Atlanta, GA 303101, Adjacent to excavation area: On or about 04/25/2022, the employer exposed employees to struck-by hazards, in that back-up alarms on the Roller (Model CP44B) were inoperable as employees on foot worked and walked in close proximity as the equipment was being operated.
Recent events (2)
- — I (S) $1989
- — Z (S) $3315
1926.651 C02
- Issued
- Penalty
- Initial $4144.00 · Current $2486.00 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Bolton Road Apartments located at 2151 Bolton Road NW, Atlanta, GA 303101, Excavation: On or about 04/25/2022, the employer exposed employees to engulfment hazards while installing 6-inch sanitary sewer pipe, in that a ladder or other safe means of egress from the excavation was not provided to employees working in an excavation measuring 13-feet wide by 7-feet deep by 30-feet long.
Recent events (2)
- — I (S) $2486.4
- — Z (S) $4144
1926.651 J02
- Issued
- Penalty
- Initial $4144.00 · Current $2486.00 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) Bolton Road Apartments located at 2151 Bolton Road NW, Atlanta, GA 303101, Excavation: On or about 04/25/2022, the employer exposed employees to cave-in/engulfment hazards while installing 6-inch sanitary sewer pipe, in that the large 20 to 25-ft., spoil piles were not kept back from the excavated edge at least 2-feet before allowing employees to work inside the excavation which was not provided with a retaining device.
Recent events (2)
- — I (S) $2486.4
- — Z (S) $4144
1926.651 K01
- Issued
- Penalty
- Initial $4144.00 · Current $2486.00 Reduced
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems. a) Bolton Road Apartments located at 2151 Bolton Road NW, Atlanta, GA 303101, Excavation: On or about 04/25/2022, the employer exposed employees to cave-in/engulfment hazards while installing 6-inch sanitary sewer pipe, in that an inspection of the excavation by a competent person was not conducted prior to allowing employees access to an excavation to perform work.
Recent events (2)
- — I (S) $2486.4
- — Z (S) $4144
1926.652 A01
- Issued
- Penalty
- Initial $5801.00 · Current $3481.00 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). a) Bolton Road Apartments located at 2151 Bolton Road NW, Atlanta, GA 303101, Excavation: On or about 04/25/2022, the employer exposed employees to cave-in/engulfment hazards while installing 6-inch sanitary sewer pipe, in that a cave-in protection system was not provided to employees engaged in pipe installation activities in an excavation which measured approximately 13-feet wide by 7-feet deep by 30-feet long.
Recent events (2)
- — I (S) $3480.6
- — Z (S) $5801
More inspections in this industry (NAICS 237110)
CHANDLER, AZ—2026-07-16
PREMIER UNDERGROUND CONSTRUCTION LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
CHICAGO, IL—2026-07-15
SUSTAINABLE SEWER & WATER INC.
LAKE FOREST, IL—2026-07-15
GREVERS CORPORATION DBA NORTH SHORE BORING
CHEYENNE, WY—2026-07-15
AZTEC CONSTRUCTION
More inspections in GA
GREENSBORO, GA—2026-07-16
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16
GF CASTING SOLUTIONS AUGUSTA, LLC
CHAMBLEE, GA—2026-07-16
U.S. DEPARTMENT OF TREASURY
DECATUR, GA—2026-07-15
PALLETS ACQUISITION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345917041.