Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WARBY PARKER OPTICAL LAB

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WARBY PARKER OPTICAL LAB in 150 ORANGE TURNPIKE, SLOATSBURG, NY 10974 (NAICS 446130). OSHA activity number 345925788.

Watch Warby Parker Optical LAB — free Get an email when a new federal OSHA severe-injury report for Warby Parker Optical LAB is published. One employer, no account, unsubscribe in one click.
Site address
150 ORANGE TURNPIKE
City
SLOATSBURG
State
NY
ZIP
10974
Mailing
150 ORANGE TURNPIKE, SLOATSBURG, NY 10974
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
446130
Employees
155
Ownership type
A

2 citations on file for this inspection.

1910.133 A01

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $8287.00 · Current $5110.00 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  location: production floor on or about: 4/26/22  a) Employees use pneumatic air to clean swarf from the inside of the MEI 4Racer TBA lens cutting machines. The employees do not wear protective eyewear.
Recent events (2)
  • — I (O) $5110
  • — Z (S) $8287

1910.147 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $10360.00 · Current $6390.00 Reduced
29 CFR  1910.147(c)(1):Energy control program. The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:   location: production floor on or about: 4/26/22  a) The employer did not have an energy control program, including specific energy control procedures, employee training and devices for isolating machines or equipment from energy sources.  Employees maintain and service equipment including but not limited to MEI 4Racer TBA lens cutting machines.
Recent events (2)
  • — I (S) $6390
  • — Z (S) $10360

OPT, LLC