OAKLAND, NJ —
OSHA Inspection: ENGINEERING LABORATORIES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ENGINEERING LABORATORIES, INC. in 360 WEST OAKLAND AVE., OAKLAND, NJ 07436 (NAICS 326199). OSHA activity number 345932875.
Where did this inspection happen?
- Establishment
- ENGINEERING LABORATORIES, INC.
- Site address
- 360 WEST OAKLAND AVE.
- City
- OAKLAND
- State
- NJ
- ZIP
- 07436
- Mailing
- 360 WEST OAKLAND AVE., OAKLAND, NJ 07436
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 30
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $3046.00 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a): Facility- Molding Department- A portable fire extinguisher was not readily accessible. Materials were placed in front of the fire extinguisher, obscuring its access, which could contribute to exacerbation of a fire, on or about May 3, 2022. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $3045.7
- — Z (S) $4351
1910.157 E01
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $3046.00 Reduced
General-duty citation text
29 CFR 1910.157(e)(1): The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace: (a): Facility- Molding Department- A fire extinguisher was not properly inspected/maintained. An inspection tag located on the fire extinguisher indicated that the fire extinguisher was past due for inspection/servicing. The tag indicated that the last inspection/service was conducted in August of 2020 and was void in August of 2021. The fire extinguisher was observed, on or about May 3, 2022. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $3045.7
- — Z (S) $4351
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $10151.00 · Current $7106.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a): Facility- Injection Molding Robots - One or more methods of machine guarding was not provided to protect the employees in the machine area from hazards created by the moving robotic components. Employees are exposed to struck-by hazards from overhead when working on or near one of the eight injection molding machine robots, on or about May 3, 2022. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d). (b): Facility -Conveyor Strippers - One or more methods of machine guarding was not provided to protect the machine operators from hazards created by the rotating conveyors. Employees are exposed to crushing and finger amputation hazards when using the conveyor strippers, on or about May 3, 2022. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $7105.7
- — Z (S) $10151
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $3046.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a): Facility- Molding Department - Sufficient access and working space was not maintained about multiple electric circuit breaker panels. Access to the circuit breaker panels was obstructed by material that was placed directly in front of the panels, on or about, May 3, 2022. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $3045.7
- — Z (S) $4351
More inspections in this industry (NAICS 326199)
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
LANESBOROUGH, MA—2026-07-08
LANSEN MOLD CO., INC.
More inspections in NJ
FREEHOLD, NJ—2026-07-10
MARIO & SONS CONSTRUCTION GROUP, LLC