DENVER, CO —
OSHA Inspection: JUAN AGUIRRE RIOS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JUAN AGUIRRE RIOS in 1842 S OGDEN ST., DENVER, CO 80210 (NAICS 238140). OSHA activity number 345942643.
Where did this inspection happen?
- Establishment
- JUAN AGUIRRE RIOS
- Site address
- 1842 S OGDEN ST.
- City
- DENVER
- State
- CO
- ZIP
- 80210
- Mailing
- 8482 JACKSON WAY, THORNTON, CO 80229
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 A01
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $2200.00 Reduced
General-duty citation text
29 CFR 1926.451(a)(1): Each scaffold and/or scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it: (a) On January 7, 2022, while in the process of installing precast chimney caps on a residential property located at 1842 S Ogden St. Denver, CO, employees working from a tubular steel framed scaffold that was not fully planked were exposed to a fall hazard. The employees fell approximately 28 feet from the top of the work platform to the ground below, when the wooden planks failed.
Recent events (2)
- — I (S) $2200
- — Z (S) $4351
1926.451 B01 I
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $2200.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary: (a) On January 7, 2022, the working platform/decking of a tubular steel framed scaffold was not fully planked, and the remaining open space between the planks were more then an inch wide thus exposing employee tasked with installing precast chimney caps on a residential property located at 1842 S Ogden St. Denver, CO 80210, to fall hazards from a height of 28 feet from the top of the working surface to the ground below.
Recent events (2)
- — I (S) $2200
- — Z (S) $4351
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $2200.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) On January 7, 2022, the employer failed to ensure that visual inspections to identify deficiencies that could affect the structural integrity of the tubular steel framed scaffolding and it components used by two employees when installing precast chimney caps on a residential property located at 1842 S Ogden St. Denver, CO 80210 was inspected by a competent person, before each work shift or anytime the scaffold was relocate/moved. Employees were exposed to fall hazards from a height of approximately 28 feet (from the working surface to the ground level).
Recent events (2)
- — I (S) $2200
- — Z (S) $4351
1926.451 G04 I
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $2200.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms: (a) On January 7, 2022, while in the process of installing precast chimney caps on a residential property located at 1842 S Ogden St. Denver, CO 80210, employees working from tubular steel framed scaffold that measured four buck-high and/or (approximately) 28 feet from the working surface to the ground below were not protected from fall hazard(s), in that a guardrail system(s) was not installed on all open sides and ends of the platform.
Recent events (2)
- — I (S) $2200
- — Z (S) $4351
1926.452 C02
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $2200.00 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): All brace connections were not secured: (a) On January 7, 2022, while in the process of installing precast chimney caps on a residential property located at 1842 S Ogden St. Denver, CO 80210, employees were exposed to a fall hazard while using a tubular steel framed scaffold that was missing one brace connection, and was not properly secured. Employees were exposed to fall hazards of approximately 28 feet, the top of the working surface to the ground below.
Recent events (2)
- — I (S) $2200
- — Z (S) $4351
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in CO
BROOMFIELD, CO—2026-07-16
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15
PCL CIVIL CONSTRUCTORS INC
Source