CINCINNATI, OH —
OSHA Inspection: PRECISION METAL BUILDING SERVICES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PRECISION METAL BUILDING SERVICES, LLC in 1280 E. KEMPER RD., CINCINNATI, OH 45246 (NAICS 238120). OSHA activity number 345963847.
Where did this inspection happen?
- Establishment
- PRECISION METAL BUILDING SERVICES, LLC
- Site address
- 1280 E. KEMPER RD.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45246
- Mailing
- 1015 AMBROSE RD., WARSAW, KY 41095
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B10
- Issued
- Penalty
- Initial $4351.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10):"Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted. (a) On March 16, 2022, located on a commercial roof, employees were exposed to a fall hazard while installing insulation at the edge of the roof and not adequately utilizing a fall protection system. The potential fall height was measured to be 16'-10 ?".
Recent events (2)
- — I (S) $2000
- — Z (S) $4351
1926.502 A02
- Issued
- Penalty
- Initial $4351.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.502(a)(2):Employers shall provide and install all fall protection systems required by this subpart for an employee, and shall comply with all other pertinent requirements of this subpart before that employee begins the work that necessitates the fall protection. (a) On May 16, 2022, located on a commercial roof, employees were exposed to a fall hazard while installing roofing insulation and the employer failed to install anchor points before employees performed the work. The potential fall height was measured to be 16'-10 1/2".
Recent events (2)
- — I (S) $0
- — Z (S) $4351
More inspections in this industry (NAICS 238120)
GARDENDALE, AL—2026-07-09
ANDINO'S IRON WORKERS, LLC
MIDLOTHIAN, VA—2026-07-09
B & J STEEL CONSTRUCTION, INC.
LYNCHBURG, VA—2026-07-09
GRAY'S WELDING LLC
CHESAPEAKE, VA—2026-07-08
MODERN STEEL AND STAIR LLC
YAKIMA, WA—2026-07-07
WA317991949 - H & A STEEL ERECTORS LLC
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345963847.