WENTZVILLE, MO —
OSHA Inspection: JS EXTERIORS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JS EXTERIORS LLC in 406 KNOTHOLE LANE, WENTZVILLE, MO 63385 (NAICS 423330). OSHA activity number 345968895.
Where did this inspection happen?
- Establishment
- JS EXTERIORS LLC
- Site address
- 406 KNOTHOLE LANE
- City
- WENTZVILLE
- State
- MO
- ZIP
- 63385
- Mailing
- 104 WESTLEIGH MANOR DRIVE, WENTZVILLE, MO 63385
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423330
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.20 B02
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $2611.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): Such programs did not provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers. On or about 5/10/2022, JS Exteriors, LLC employees were actively installing siding on a residence located at 406 Knothole Lane in Wentzville, MO. JS Exteriors, LLC, the controlling contractor, did not conduct an adequate inspection of the job site, materials, and equipment. The employees were exposed to the following hazards: a)An employee was working from pump jack scaffolding on the side of the residence, approximately 12 feet above the ground, without utilizing fall protection. b)Three employees were installing siding on a chimney on a 10/12 sloped roof 12-18 feet above the ground without utilizing fall protection. c)The pump jack scaffolding was not secured at the bottom with triangular bracing to prevent displacement.
Recent events (2)
- — I (S) $2610.6
- — Z (S) $4351
1926.451 C02 I
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement. On or about 5/10/2022, JS Exteriors, LLC employees were actively installing siding on a residence located at 406 Knothole Lane in Wentzville, Mo. One employee worked from the pump jack scaffolding. Two out of three poles supporting the pump jack scaffolding were not on level and sound footings to prevent displacement. The three pump jack scaffolding poles were also not secured by triangular bracing to prevent displacement.
Recent events (2)
- — I (S) $0
- — Z (S) $4351
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. On or about 5/10/2022, JS Exteriors, LLC employees were actively installing siding on a residence located at 406 Knothole Lane in Wentzville, MO. One employee was working from pump jack scaffolding on the side of the residence, 10-12 feet above the ground, without utilizing fall protection.
Recent events (2)
- — I (S) $0
- — Z (S) $4351
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. On or about 5/10/2022, JS Exteriors, LLC employees were actively installing siding on a residence located at 406 Knothole Lane in Wentzville, Mo. One employee was working from the pump jack scaffolding on the side of the residence. The three poles of the pump jack scaffolding system were not secured to the structure by rigid triangular bracing or equivalent means at the bottom.
Recent events (2)
- — I (S) $0
- — Z (S) $4351
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest systems. On or about 5/10/2022, JS Exteriors, LLC employees were actively installing siding on the chimney of a residence located at 406 Knothole Lane in Wentzville, MO. Three employees were observed on the roof 10/12 sloped roof, approximately 12 to 18 feet above the ground, without utilizing fall protection.
Recent events (2)
- — I (S) $0
- — Z (S) $4351
More inspections in this industry (NAICS 423330)
SPOKANE VALLEY, WA—2026-07-15
WA317992075 - SRS DISTRIBUTION INC
KLAMATH FALLS, OR—2026-07-07
317744722 - NORTHWEST QUALITY ROOFING LLC
PORT ORCHARD, WA—2026-06-25
WA317991918 - CONVOY SUPPLY INC
ROSEVILLE, CA—2026-06-23
RWC BUILDING PRODUCTS - SACRAMENTO
PASADENA, TX—2026-06-22
IDEAL PRODUCTS OF AMERICA
More inspections in MO
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
Source