Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JS EXTERIORS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JS EXTERIORS LLC in 406 KNOTHOLE LANE, WENTZVILLE, MO 63385 (NAICS 423330). OSHA activity number 345968895.

Watch JS Exteriors LLC — free Get an email when a new federal OSHA severe-injury report for JS Exteriors LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JS EXTERIORS LLC
Site address
406 KNOTHOLE LANE
City
WENTZVILLE
State
MO
ZIP
63385
Mailing
104 WESTLEIGH MANOR DRIVE, WENTZVILLE, MO 63385
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423330
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $4351.00 · Current $2611.00 Reduced
29 CFR 1926.20(b)(2): Such programs did not provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  On or about 5/10/2022,  JS Exteriors, LLC employees were actively installing siding on a residence located at 406 Knothole Lane in Wentzville, MO. JS Exteriors, LLC, the controlling contractor, did not conduct an adequate inspection of the job site, materials, and equipment.  The employees were exposed to the following hazards:  a)An employee was working from pump jack scaffolding on the side of the residence, approximately 12 feet above the ground, without utilizing fall protection.    b)Three employees were installing siding on a chimney on a 10/12 sloped roof 12-18 feet above the ground without utilizing fall protection.    c)The pump jack scaffolding was not secured at the bottom with triangular bracing  to prevent displacement.
Recent events (2)
  • — I (S) $2610.6
  • — Z (S) $4351

1926.451 C02 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4351.00 · Current $0.00 Reduced
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.  On or about 5/10/2022, JS Exteriors, LLC employees were actively installing siding on a residence located at 406 Knothole Lane in Wentzville, Mo.  One employee worked from the pump jack scaffolding. Two out of three poles supporting the pump jack scaffolding were not on level and sound footings to prevent displacement.  The three pump jack scaffolding poles were also not secured by triangular bracing to prevent displacement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4351

1926.451 G01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4351.00 · Current $0.00 Reduced
29 CFR  1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part.   On or about 5/10/2022,  JS Exteriors, LLC employees were actively installing siding on a residence located at 406 Knothole Lane in Wentzville, MO.  One employee was working from pump jack scaffolding on the side of the residence, 10-12 feet above the ground, without utilizing fall protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4351

1926.452 J02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4351.00 · Current $0.00 Reduced
29 CFR  1926.452(j)(2):  Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.   On or about 5/10/2022, JS Exteriors, LLC employees were actively installing siding on a residence located at 406 Knothole Lane in Wentzville, Mo.  One employee was working from the pump jack scaffolding on the side of the residence. The three poles of the pump jack scaffolding system were not secured to the structure by rigid triangular bracing or equivalent means at the bottom.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4351

1926.501 B13

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4351.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest systems.  On or about 5/10/2022,  JS Exteriors, LLC employees were actively installing siding on the chimney of a residence located at 406 Knothole Lane in Wentzville, MO.  Three employees were observed on the roof 10/12 sloped roof, approximately 12 to 18 feet above the ground, without utilizing fall protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4351

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345968895.