Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CASA JADE EQUITY, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CASA JADE EQUITY, LLC in 9017 RIVERSIDE PLACE, NORTH BERGEN, NJ 07047 (NAICS 238140). OSHA activity number 346001795.

Watch Casa Jade Equity, LLC — free Get an email when a new federal OSHA severe-injury report for Casa Jade Equity, LLC is published. One employer, no account, unsubscribe in one click.
Site address
9017 RIVERSIDE PLACE
City
NORTH BERGEN
State
NJ
ZIP
07047
Mailing
9005 RIVERSIDE PLACE, NORTH BERGEN, NJ 07047
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.451 C02

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $4351.00 · Current $0.00 Reduced
29 CFR  1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates and mud sills or other adequate firm foundation:  a. 9017 Riverside Place North Bergen, NJ  Employees engaged in masonry activities on the third tier of a job made scaffold that did not have mud sills or base plates to support the scaffold exposed the employees to fall hazards of approximately 20 feet.  Violations occurred on or about 04/27/2022
Recent events (2)
  • — I (S) $0
  • — Z (S) $4351

1926.451 F06

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $4351.00 · Current $3096.00 Reduced
29 CFR  1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).  a. 9017 Riverside Place North Bergen, NJ  Employees engaged in masonry activities were exposed to electrocution hazards while working from a scaffold that was erected less than 1 foot from a power drop of less than 300 volts.  Violation occurred on or about 04/27/2022
Recent events (2)
  • — I (S) $3096
  • — Z (S) $4351

1926.451 G01 VII

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $4351.00 · Current $3000.00 Reduced
29 CFR  1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  a. 9017 Riverside Place North Bergen, NJ  Employees performing painting and siding operations on a wooden job made scaffold were not protected from fall hazards by the use of personal fall arrest systems or guardrail systems.  Violation observed on or about 04/27/2022
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4351

1926.452 I08

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $4351.00 · Current $0.00 Reduced
29 CFR  1926.452(i)(8): 29 CFR 1926.452(i)(8):  Scaffolds and scaffold components were not designed by a registered professional engineer and were not constructed and loaded in accordance with such design:  a. 9017 Riverside Place North Bergen, NJ  The job made supported scaffold system was not designed by a registered professional engineer, exposing employees, installing the fascia, to a 20 foot fall hazard.  Violations occurred on or about 04/27/2022
Recent events (2)
  • — I (S) $0
  • — Z (S) $4351

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346001795.