Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: Y & M CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of Y & M CONSTRUCTION LLC in 2174 RICHVILLE DR SE, MASSILLON, OH 44646 (NAICS 238160). OSHA activity number 346002595.

Watch Y & M Construction LLC — free Get an email when a new federal OSHA severe-injury report for Y & M Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
2174 RICHVILLE DR SE
City
MASSILLON
State
OH
ZIP
44646
Mailing
5344 SMITH KRAMER ST NE, HARTVILLE, OH 44632
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3729.00 · Current $1865.00 Reduced
29 CFR  1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   On or about June 6, 2022, during the installation of roofing material at a job site located at 2174 Richville Dr. SE, Massillon, Ohio 44646; the employer did not ensure that all employees working on the roof of a single family home were protected from a fall of approximately 11.3 feet by utilizing a fall protection system.
Recent events (2)
  • — I (S) $1865
  • — Z (S) $3729

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3729.00 · Current $743.00 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  On or about June 6, 2022 at the job site located at 2174 Richville Dr. SE, Massillon, Ohio 44646; during the installation of roofing material on a residential roof, the employer did not ensure portable ladders extended 3 feet above the upper landing surface.