QUAKERTOWN, PA —
OSHA Inspection: TOP PEAK ROOFING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TOP PEAK ROOFING LLC in 1770 WENTZ RD, QUAKERTOWN, PA 18951 (NAICS 238160). OSHA activity number 346014855.
Where did this inspection happen?
- Establishment
- TOP PEAK ROOFING LLC
- Site address
- 1770 WENTZ RD
- City
- QUAKERTOWN
- State
- PA
- ZIP
- 18951
- Mailing
- 105 PENNSYLVANIA AVENUE, NORTH WALES, PA 19454
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $3916.00 · Current $3916.00
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 1770 Wentz Rd, Quakertown, PA 18951: On or about June 13, 2022, employees performing roofing work, approximately 20 feet above grade, were exposed to fall hazards when not provided an appropriate means of fall protection.
Recent events (1)
- — Z (S) $3916
1926.1053 B01
- Issued
- Penalty
- Initial $2797.00 · Current $2797.00
General-duty citation text
29 CFR 1926.1053(b)(1):Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) 1770 Wentz Rd, Quakertown, PA 18951: On or about June 13, 2022, employees were using multiple portable ladders for access to and egress from the roof, the ladders side rails did not extend at least 3 feet (.9 m) above the roof to which the ladders were used to gain access.
Recent events (1)
- — Z (S) $2797
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source