STANLEY, WI —
OSHA Inspection: HOOVER'S CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HOOVER'S CONSTRUCTION in STANLEY CITY HALL & POLICE DEPARTMENT 353 S BROADWAY ST., STANLEY, WI 54768 (NAICS 238160). OSHA activity number 346025893.
Where did this inspection happen?
- Establishment
- HOOVER'S CONSTRUCTION
- Site address
- STANLEY CITY HALL & POLICE DEPARTMENT 353 S BROADWAY ST.
- City
- STANLEY
- State
- WI
- ZIP
- 54768
- Mailing
- N13809 THOMAS AVE., WITHEE, WI 54498
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B11
- Issued
- Penalty
- Initial $4351.00 · Current $3046.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11):Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: (a) West side of roof; Fall protection systems were not used during reroofing operations on a commercial roof with approximate eave height of 10 feet, 7 inches.
Recent events (2)
- — I (S) $3045.7
- — Z (S) $4351
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) Throughout the establishment; Fall protection training was not provided before employees were allowed to perform elevated reroofing activities on a commercial roof with an approximate eave height of 10 feet, 7 inches.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Penalty
- Initial $1585.00 · Current $1110.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) West side of roof; Side rails of an aluminum ladder used for roof access and egress did not extend at least 3 feet above the roof edge (upper landing surface) and an additional grabrail and/or grasping device was not provided.
Recent events (2)
- — I (S) $1109.5
- — Z (S) $1585
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346025893.