Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SYD EXTERIORS LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SYD EXTERIORS LLC in 2258 JODI CIRCLE, HUDSON, WI 54016 (NAICS 238160). OSHA activity number 346055049.

Watch SYD Exteriors LLC — free Get an email when a new federal OSHA severe-injury report for SYD Exteriors LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SYD EXTERIORS LLC
Site address
2258 JODI CIRCLE
City
HUDSON
State
WI
ZIP
54016
Mailing
1610 PLEASANT VIEW COURT, ROCKFORD, IL 61107
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4351.00 · Current $4351.00
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  (a) Residential roof structure, various locations; Employees performing roofing replacement work from a steep-slope roof were not protected from falls while working at heights ranging from approximately 7.5 feet to 27 feet, 7 inches above lower levels.
Recent events (1)
  • — Z (S) $4351

1926.503 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record:  (a) Residential roof structure, various locations; When employees were exposed to fall hazards at heights ranging from approximately 7.5 feet to 27 feet, 7 inches above lower levels, the employer did not prepare a written certification record to verify employees received training on applicable topics, including but not limited to, fall hazard recognition and mitigation procedures.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $3108.00 · Current $3108.00
29 CFR  1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:  (a) North end of residential structure, ground-level; A 12-foot Werner brand model 7112-1 fiberglass straight ladder used by employees for roof access was not of sufficient height to allow for the side rails to extend at least 3 feet above the landing surface, was not secured to prevent displacement, and a grasping device was not provided.
Recent events (1)
  • — Z (S) $3108

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346055049.