Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ALLIED UNIVERSAL SECURITY SERVICES INCORPORATED

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ALLIED UNIVERSAL SECURITY SERVICES INCORPORATED in 10155 MONROE DRIVE, DALLAS, TX 75229 (NAICS 561612). OSHA activity number 346084254.

Watch Allied Universal Security Services Incorporated — free Get an email when a new federal OSHA severe-injury report for Allied Universal Security Services Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
10155 MONROE DRIVE
City
DALLAS
State
TX
ZIP
75229
Mailing
3011 GATEWAY DRIVE SUITE 200, IRVING, TX 75063
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561612
Employees
25
Ownership type
A

2 citations on file for this inspection.

1910.305 G02 III

Other-than-serious Gravity 10 1 instance 5 exposed
Issued
Penalty
Initial $14502.00 · Current $6215.00 Reduced
29 CFR  1910.305(g)(2)(iii):Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a) On or about July 14, 2022, and at times prior thereto, in the outdoor break area, where security personnel were exposed to electric shock hazards when they used a golf cart charger that had damaged strain relief at the golf cart battery plug and the outlet cord.
Recent events (2)
  • — I (O) $6215
  • — Z (S) $14502

1910.334 A02 II

Other-than-serious Gravity 10 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  (a) On or about July 14, 2022, and at times prior thereto, in the outdoor break area, where security personnel were exposed to electric shock hazards when they used a golf cart charger that had damaged strain relief and the charger had not been removed from service.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0