PULASKI, WI —
OSHA Inspection: OBC ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OBC ROOFING in 519 E GLENBROOK DRIVE, PULASKI, WI 54162 (NAICS 238160). OSHA activity number 346093297.
Where did this inspection happen?
- Establishment
- OBC ROOFING
- Site address
- 519 E GLENBROOK DRIVE
- City
- PULASKI
- State
- WI
- ZIP
- 54162
- Mailing
- N8226 KAY DRIVE, BEAVER DAM, WI 53916
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $4351.00 · Current $2175.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. On or about July 21, 2022, at the worksite located at 519 E Glenbrook Drive, Pulaski, WI 54162, the employer did not ensure that each employee working on a roof was protected from falls, exposing employees to fall hazards. The eave height of the roof was greater than 15 feet and the roof pitch was approximately 4/12. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.
Recent events (2)
- — I (S) $2175
- — Z (S) $4351
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source