Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JEREMIAH GUNTER

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JEREMIAH GUNTER in 3443 LIVERPOOL UNIT 2, BLDG 6, IDAHO FALLS, ID 83401 (NAICS 238130). OSHA activity number 346105661.

Watch Jeremiah Gunter — free Get an email when a new federal OSHA severe-injury report for Jeremiah Gunter is published. One employer, no account, unsubscribe in one click.
Establishment
JEREMIAH GUNTER
Site address
3443 LIVERPOOL UNIT 2, BLDG 6
City
IDAHO FALLS
State
ID
ZIP
83401
Mailing
10810 N CUMBERLAND ROAD, POCATELLO, ID 83202
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2486.00 · Current $1500.00 Reduced
29 CFR  1926.102(a)(1):29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  (a) Employees using pneumatic nail guns and power saws for framing activities were not wearing approved eye protection  NOTE: Certification of corrective action (abatement) is required for this item.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2486

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2486.00 · Current $1500.00 Reduced
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   (a)  Employees engaged in framing activities, including installing sheathing, on an approximate 4:12 to 5:12 pitched roof, were not provided or using an acceptable means of fall protection.  The ground to eave height was approximately 9.8 feet, to approximately 15 feet near the peak.   NOTE:  Certification of corrective action (abatement) is required for this item.