OSHA Inspection: HOURIGAN CONSTRUCTION CORP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HOURIGAN CONSTRUCTION CORP in NAVAL STATION DAM NECK CHAMBERLIN HALL BUILDING 102, VIRGINIA BEACH, VA 23460 (NAICS 236220). OSHA activity number 346107345.

Watch Hourigan Construction Corp — free Get an email when a new federal OSHA severe-injury report for Hourigan Construction Corp is published. One employer, no account, unsubscribe in one click.
Site address
NAVAL STATION DAM NECK CHAMBERLIN HALL BUILDING 102
City
VIRGINIA BEACH
State
VA
ZIP
23460
Mailing
4429 BONNEY ROAD SUITE 200, VIRGINIA BEACH, VA 23462
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
243
Ownership type
A

5 citations on file for this inspection.

1926.34 B

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $7925.00 · Current $0.00 Reduced
29 CFR 1926.34(b): Exits and access to exits were not marked by a readily visible sign:  a)	Building 102, Chamberlain Hall: On or about 07/27/2022, not all exits and access to exit signs were visible or posted throughout the building:   Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7925

1926.34 C

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $7925.00
29 CFR  1926.34(c): Means of egress was not continually maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency:  a)	Building 102, Chamberlain Hall, second floor: On or about 07/27/2022, means of egress was not continually maintained free of all obstructions in that electrical conduits, pipes, and brackets were installed on the floor in the main corridor thereby exposing subcontractors and employees to trip hazards in the event an emergency evacuation.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $7925
  • — Z (S) $0

1926.416 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7925.00 · Current $7925.00
29 CFR 1926.416(b)(2): Working spaces, walkways, and similar locations were not kept clear of cords which created a hazard to employees:  a)	Building 102, Chamberlain Hall, second floor: On or about 07/27/2022, the working spaces and walkway were not kept clear of cords in that multiple 100ft extension cords were placed on the floor, ran across sharp metal frames, and into walkway to supply power to fans thus exposed multiple subcontractors to a possible electric shock or trip hazard.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $7925
  • — Z (S) $7925

1904.41 A01

Other-than-serious 1 instance 243 exposed
Issued
Penalty
Initial $1347.00 · Current $0.00 Reduced
29 CFR 1904.41(a)(1): If your establishment had 250 or more employees at any time during the previous calendar year, and this part requires your establishment to keep records, then you must electronically submit information from the three recordkeeping forms that you keep under this part (OSHA Form 300A Summary of Work-Related Injuries and Illnesses, OSHA Form 300 Log of Work-Related Injuries and Illnesses, and OSHA Form 301 Injury and Illness Incident Report) to OSHA or OSHA's designee. You must submit the information once a year, no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the forms:  a)  Hourigan Construction Corporation 411 E Franklin Street Suite 400, Richmond VA 23219: On or about July 27, 2022, the employer failed during calendar year 2021, to electronically submit information from their OSHA Form 300A or equivalent by 03/02/2022.   The establishment employed 259 employees and is classified 236220 during calendar year 2021.  No abatement certification or documentation required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1347

1926.403 B02

Other-than-serious 1 instance 8 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:   a)	Building 102, Chamberlain Hall, second floor: On or about 07/27/2022, multiple 100ft extension cords were not used in accordance with its listing and label, in that the subcontractors daisy chained 100ft extension cords to supply power to portable fans.   No abatement certification or documentation required.