Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DPT LABORATORIES LTD.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DPT LABORATORIES LTD. in 5303 DISTRIBUTION, SAN ANTONIO, TX 78218 (NAICS 325412). OSHA activity number 346139785.

Watch DPT Laboratories LTD. — free Get an email when a new federal OSHA severe-injury report for DPT Laboratories LTD. is published. One employer, no account, unsubscribe in one click.
Site address
5303 DISTRIBUTION
City
SAN ANTONIO
State
TX
ZIP
78218
Mailing
5303 DISTRIBUTION, SAN ANTONIO, TX 78218
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325412
Employees
40
Ownership type
A

5 citations on file for this inspection.

1910.119 F01 II A

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $11666.00 Reduced
29 CFR  1910.119(f)(1)(ii)(A):Consequences of deviation;   (a) On August 10, 2022, and at times prior, at the facility located at 5303 Distribution, San Antonio, TX, the Gas House operating procedures including SOP-001910475 did not identify the consequences of deviation and the steps required to correct or avoid deviation.
Recent events (3)
  • — F (O) $11666
  • — C (S) $15625
  • — Z (S) $15625

1910.119 H02 I

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $11162.00 · Current $0.00 Reduced
29 CFR  1910.119(h)(2)(i): The employer, when selecting a contractor, did not obtain and evaluate information regarding the contract employer's safety performance and program:  (a) On August 10, 2022, and at times prior,  at the facility located at 5303 Distribution, San Antonio, TX, the employer did not obtain and evaluate Gunderson Systems' safety information and programs before hiring the subcontractor to perform work on covered process equipment.  (b) On August 10, 2022, and at times prior, at the facility located at 5303 Distribution, San Antonio, TX, the employer did not obtain and evaluate Rothe SA's safety information and programs before allowing the subcontractor to perform work on covered process equipment.
Recent events (3)
  • — F (S) $0
  • — C (S) $11162
  • — Z (S) $11162

1910.119 H02 V

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11162.00 · Current $0.00 Reduced
29 CFR  1910.119(h)(2)(v): The employer shall periodically evaluate the performance of contract employers in fulfilling their obligations as specified in paragraph (h)(3) of this section:  (a) On August 10, 2022, and at times prior, at the facility located at 5303 Distribution, San Antonio, TX, the host employer did not periodically evaluate the performance of its contractors in fulfilling their obligations under (h)(3)
Recent events (3)
  • — F (S) $0
  • — C (S) $11162
  • — Z (S) $11162

1910.119 J02

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $11666.00 Reduced
29 CFR  1910.119(j)(2): The employer did not establish written procedures to maintain the on-going integrity of process equipment:  (a) On August 10, 2022, and at times prior, at the facility located at 5303 Distribution, San Antonio, TX,  the employer did not establish written procedures to maintain the on-going integrity of process equipment including the gas house process equipment.
Recent events (3)
  • — F (O) $11666
  • — C (S) $15625
  • — Z (S) $15625

1910.119 J04 III

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $11666.00 Reduced
29 CFR  1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment shall be consistent with applicable manufacturers' recommendations and good engineering practices, and more frequently if determined to be necessary by prior operating experience.  (a) On August 10, 2022, and at times prior, at the facility located at 5303 Distribution, San Antonio, TX, the employer did not ensure that the inspection/tests on safety equipment including monitoring devices, sensors, alarms, and interlocks in the gas house were performed on a schedule that is consistent with the applicable manufacturer's recommendations and good engineering practices.
Recent events (3)
  • — F (O) $11666
  • — C (S) $15625
  • — Z (S) $15625

View DPT LABORATORIES LTD.'s full OSHA safety record →