Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUPERIOR COMFORT INCORPORATED

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SUPERIOR COMFORT INCORPORATED in 11 BROADCOMMON ROAD, BRISTOL, RI 02809 (NAICS 238220). OSHA activity number 346140890.

Watch Superior Comfort Incorporated — free Get an email when a new federal OSHA severe-injury report for Superior Comfort Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
11 BROADCOMMON ROAD
City
BRISTOL
State
RI
ZIP
02809
Mailing
11 BROADCOMMON ROAD, BRISTOL, RI 02809
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
48
Ownership type
A

3 citations on file for this inspection.

1910.146 C01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $877.00 · Current $439.00 Reduced
29 CFR  1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:  (a) In the attic at 36 Alyssa Ct in Hope RI:  On or about 8-4-2022, the employer did not evaluate the workplace to determine if  the HVAC system enclosure was a permit-required confined space when employees had to enter to perform work.
Recent events (2)
  • — I (O) $438.5
  • — Z (O) $877

1910.146 C04

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:  (a) In the attic at 36 Alyssa Ct in Hope RI:  On or about 8-4-2022, when the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C05 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $877.00 · Current $439.00 Reduced
29 CFR  1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:  (a) In the attic at 36 Alyssa Ct in Hope RI:  On or about 8-4-2022, a means of locking out the power supply to the HVAC system was not provided by the employer for isolating, securing or blocking of machines and/or equipment from energy sources.
Recent events (2)
  • — I (O) $438.5
  • — Z (O) $877