OSHA Inspection: CENTRE WISP VENTURE COMPANY, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of CENTRE WISP VENTURE COMPANY, LLC in 130 TRESSLER LANE, SPRING MILLS, PA 16875 (NAICS 517312). OSHA activity number 346143829.

Watch Centre Wisp Venture Company, LLC — free Get an email when a new federal OSHA severe-injury report for Centre Wisp Venture Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
130 TRESSLER LANE
City
SPRING MILLS
State
PA
ZIP
16875
Mailing
2826 EARLYSTOWN ROAD, SPRING MILLS, PA 16875
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
517312
Employees
11
Ownership type
A

5 citations on file for this inspection.

1910.67 C02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4465.00 · Current $9328.00
29 CFR  1910.67(c)(2)(v):A personal fall arrest or travel restraint system that meets the requirements in subpart I of this part was not worn and attached to the boom or basket when working from an aerial lift:  a) 130 Tressler Lane Spring Mills, PA Residential Cabin - An employee was working in the bucket of a  Chevy C5500 Utility Truck without the use of personal fall arrest or travel restraint system,, on or about August 10, 2022.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $9328
  • — Z (S) $4465

1910.67 C02 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $0.00 Reduced
29 CFR  1910.67(c)(2)(vii): The brakes were not set and outriggers were not positioned on pads or a solid surface. Wheel chocks were not  installed before using an aerial lift on an incline.  a) 130 Tressler Lane Spring Mills, PA Residential Cabin - Wheel chocks were not installed prior to an employee utilizing a Chevy C5500 Utility Truck which was positioned on an incline., on or about August 10, 2022.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3572

1910.268 B07

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $9328.00 Reduced
29 CFR  1910.268(b)(7): The employer did not ensure that no employee approached or took any conductive object closer to any electrically energized overhead power lines and parts than prescribed in Table R-2 or in (i) - (iii) of this section:   a) 130 Tressler Lane Spring Mills, PA Residential Cabin - An employee working in a bucket of a Chevy C5500 Utility Truck breached the approach distance and contacted the 7200-volt power line, on or about August 10, 2022., on or about August 10, 2022.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $9328
  • — Z (S) $15625

1910.268 J03

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.268(j)(3): Vehicle-mounted elevating and rotating work platforms shall not be operated with any conductive part of the equipment closer to exposed energized power lines than the clearances set forth in Table R-2 of this section.   a) 130 Tressler Lane Spring Mills, PA Residential Cabin - The uninsulated articulating arm and bucket of a Chevy C5500 Utility Truck was operated in the vicinity of energized 7200-volt overhead lines, on or about August 10, 2022, on or about August 10, 2022.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.268 C

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $9328.00 Reduced
29 CFR  1910.268(c): The employer did not provide training in the various precautions and safe practices described in (1) through (3) of this section and did not ensure that employees did not engage in the activities to which this section applies until such employees have received proper training in the various precautions and safe practices required by this section.   a) 130 Tressler Lane Spring Mills, PA Residential Cabin - An employee working in a bucket of a Chevy C5500 Utility Truck did not have the training and familiarity of the necessary safety- related work practices to conduct work activities around  7200-volt power line, on or about August 10, 2022.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $9328
  • — Z (S) $15625