Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BK PLASTICS INDUSTRY, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of BK PLASTICS INDUSTRY, INC. in 13414 BYRD DR., ODESSA, FL 33556 (NAICS 326199). OSHA activity number 346144017.

Watch BK Plastics Industry, INC. — free Get an email when a new federal OSHA severe-injury report for BK Plastics Industry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
13414 BYRD DR.
City
ODESSA
State
FL
ZIP
33556
Mailing
13414 BYRD DR., ODESSA, FL 33556
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
18
Ownership type
A

5 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $2143.00 Reduced
29 CFR  1910.37(a)(3):  Exit route(s) were not kept free and unobstructed:  a.  At the south area of the Molding Department:  On or about August 8, 2022, the emergency exit access was obstructed by palletized plastic sheets and other palletized material, restricting  employee movement through the exit access and preventing quick access to the exit.  b. At the east side area of the Molding Department: On or about August 8, 2022, the emergency exit access was obstructed by a compressed cylinder, wood working tables and boxes of scraps, restricting  employee movement through the exit access and preventing quick access to the exit.
Recent events (2)
  • — I (S) $2143.2
  • — Z (S) $3572

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $4465.00 · Current $2679.00 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a.  At station 5 of the Molding Department:  On or about August 8, 2022, employees were exposed to struck-by hazards, in that, the unused portion of the blade on the JET 18-inch (Model: JWBS-18QT / S/N: 1203842) bandsaw was not guarded, exposing employees to a struck-by hazards created by the cutting  motion of the blade.
Recent events (2)
  • — I (S) $2679
  • — Z (S) $4465

1910.303 G01 II

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $5358.00 · Current $3215.00 Reduced
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a.  At the north-east side of the Molding Department:  On or about August 8, 2022, palletized material and boxes were stored in the working space of molding machine 2 and the air compressor disconnect switches, a square D safety switch and two main breaker panels.
Recent events (2)
  • — I (S) $3214.8
  • — Z (S) $5358

1910.305 G01 IV A

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   a:  At stations 1 thru 5 of the Molding Department:  On or about August 8, 2022, flexible cords were used as a substitute for the wiring of the bandsaws , lamps and motors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):   a:  At station 1 of the Molding Department:  On or about August 8, 2022, the powered cord of the Dayton Blower (Model 1TDT5) was not inspected for damage prior to the start of the shift, in that, the outer sheath cover was damaged and covered with electrical tape.  b. At station 1 of the Molding Department:  On or about August 8, 2022, the powered cord of the bandsaw motor was not inspected for damage prior to the start of the shift, in that, the outer sheath cover was damaged.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View BK PLASTICS INDUSTRY, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346144017.