1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: LEWIS PETRO PROPERTIES, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of LEWIS PETRO PROPERTIES, INC. in 28.345307? N, -99.050695? W, COTULLA, TX 78014 (NAICS 213111). OSHA activity number 346160815.

Watch Lewis Petro Properties, INC. — free Get an email when a new federal OSHA severe-injury report for Lewis Petro Properties, INC. is published. One employer, no account, unsubscribe in one click.
Site address
28.345307? N, -99.050695? W
City
COTULLA
State
TX
ZIP
78014
Mailing
10101 REUNION PLACE SUITE 1000, SAN ANTONIO, TX 78216
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
800
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $9375.00 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):   On or about August 17, 2022, and at times prior thereto, the energy control procedures for the Liberty Lift Pumping Unit/Pump Jack (Model: EG 640-365-168) did not clearly and specifically outline the techniques to be used for the control of gravitational (potential) energy, exposing employees to struck-by and caught-in hazards from rotating parts such as the counterweight.
Recent events (2)
  • — I (S) $9375
  • — Z (S) $15625

1910.147 C05 I

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $15625.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing, or blocking of machines or equipment from energy sources:   On or about August 17, 2022, and at time prior thereto, the employer did not ensure that employees have available lockout/tagout devices and other hardware to be used for shutting down, isolated, blocked and secured energized machines or equipment such as Liberty Lift Pumping Unit/Pump Jack (Model: EG 640-365-168), exposing employees to struck-by, caught-in or -between hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $15625

1910.147 C06 I

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $15625.00 · Current $9375.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:   On or about August 17, 2022, and at time prior thereto, the employer did not conduct an annual inspection of the energy control procedure for Liberty Lift Pumping Unit/Pump Jack (Model: EG 640-365-168), exposing employees to struck-by, caught-in or -between hazards.
Recent events (2)
  • — I (S) $9375
  • — Z (S) $15625

1910.147 C07 I

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $15625.00 · Current $9375.00 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:   On or about August 17, 2022, and at time prior thereto, the employer did not train his employees on Lockout/Tagout program and its elements required for isolating hazardous energies for machinery, such as, but not limited to Liberty Lift Pumping Unit/Pump Jack (Model: EG 640-365-168), exposing employees to struck-by, caught-in or -between hazards.
Recent events (2)
  • — I (S) $9375
  • — Z (S) $15625

1910.147 D03

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $9375.00 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):   On or about August 17, 2022, and at time prior thereto, the energy sources of the Liberty Lift Pumping Unit/Pump Jack (Model: EG 640-365-168) were not isolated, exposing employees to struck-by, caught-in or -between hazards.
Recent events (2)
  • — I (S) $9375
  • — Z (S) $15625

1910.147 D05 I

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices:   On or about August 17, 2022, and at time prior thereto, all potentially hazardous energies of the of the Liberty Lift Pumping Unit/Pump Jack (Model: EG 640-365-168) were not restrained, exposing employees to struck-by, caught-in or -between hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View LEWIS PETRO PROPERTIES, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346160815.