2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: OCEANX

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of OCEANX in 6390 COMMERCE COURT, GROVEPORT, OH 43125 (NAICS 454110). OSHA activity number 346171119.

Watch Oceanx — free Get an email when a new federal OSHA severe-injury report for Oceanx is published. One employer, no account, unsubscribe in one click.
Establishment
OCEANX
Site address
6390 COMMERCE COURT
City
GROVEPORT
State
OH
ZIP
43125
Mailing
6390 COMMERCE COURT, GROVEPORT, OH 43125
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
454110
Employees
150
Ownership type
A

2 citations on file for this inspection.

1910.22 A03

Serious Gravity 1 1 instance 60 exposed
Issued
Abate by
Penalty
Initial $4754.00 · Current $4754.00
29 CFR 1910.22(a):  Surface conditions.  The employer must ensure:   29 CFR  1910.22(a)(3): Walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.  a. On or about August 25, 2022, multiple extension cords were used to supply electricity to industrial fans at work areas, such as but not limited to, Line 4, thereby exposing employees walking and working along the line to trip hazards.
Recent events (1)
  • — Z (S) $4754

1910.305 G02 II

Serious Gravity 1 1 instance 30 exposed
Issued
Penalty
Initial $4754.00 · Current $4754.00
1910.305(g)(2)(ii): Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.  a. Located at 6390 Commerce Court, Groveport, Ohio: On or about August 25, 2022, multiple interconnected flexible cords were used in the B2B-CO2 area between emergency exit M203 and M204 in order to power two industrial fans, thereby exposing employees to electrical fire hazards.