Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CARDINAL DRYWALL, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of CARDINAL DRYWALL, LLC in 16158-16160 S. LA GRANGE RD., ORLAND PARK, IL 60467 (NAICS 238310). OSHA activity number 346193758.

Watch Cardinal Drywall, LLC — free Get an email when a new federal OSHA severe-injury report for Cardinal Drywall, LLC is published. One employer, no account, unsubscribe in one click.
Site address
16158-16160 S. LA GRANGE RD.
City
ORLAND PARK
State
IL
ZIP
60467
Mailing
801 BROOKVIEW DR., BYRON, IL 61010
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.405 A02 II E

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $3729.00 · Current $0.00 Reduced
29 CFR  1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:  a.  On or about August 31, 2022, at the above addressed jobsite, employees performing drywall installation activities were using temporary lighting for general illumination that was not protected from accidental contact or breakage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3729

1926.405 B02

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $3729.00 · Current $0.00 Reduced
29 CFR  1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers:  a.  On or about August 31, 2022, at the above addressed jobsite, employees performing drywall installations operations were exposed to electrical hazards due to the presence of uncovered live electrical boxes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3729

1926.405 J01 III

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $3729.00 · Current $0.00 Reduced
29 CFR  1926.405(j)(1)(iii): Portable lamps were not wired with flexible cord and an attachment plug of the polarized or grounding type:  a.  On or about August 31, 2022, at the above addressed jobsite, employees performing drywall installation activities near temporary lighting that was not provided with an attachment plug were exposed to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3729

1926.1052 C01

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $2486.00 · Current $2000.00 Reduced
29 CFR  1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge:  a.  On or about August 31, 2022, at the above addressed jobsite, stairways used to gain access to the upper levels were not equipped with at least one handrail and one stairrail system along each unprotected side or edge, thereby exposing employees to slips, trips, and fall hazards.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $2486

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346193758.