1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: TODPAT, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of TODPAT, LLC in POWELL 33-6, ODESSA, TX 79760 (NAICS 213111). OSHA activity number 346206816.

Watch Todpat, LLC — free Get an email when a new federal OSHA severe-injury report for Todpat, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
TODPAT, LLC
Site address
POWELL 33-6
City
ODESSA
State
TX
ZIP
79760
Mailing
3460 S. FULTON AVE., ODESSA, TX 79766
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
13
Ownership type
A

4 citations on file for this inspection.

1910.28 B01 I

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5801.00 · Current $4000.00 Reduced
29 CFR  1910.28(b)(1)(i):(1) Unprotected sides and edges.  (i) Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the following: (A) Guardrail systems; (B) Safety net systems; or (C) Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems.  On or about September 8, 2022, employees engaged in performing pump jack servicing were exposed to fall hazards in excess of four feet.
Recent events (2)
  • — I (O) $4000
  • — Z (S) $5801

1910.147 C04 II B

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5801.00 · Current $5000.00 Reduced
29 CFR  1910.147(c)(4)(ii)(B):The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.  On or about September 8,  2022, employees engaged in pumpjack repair were exposed to caught-in hazards as the employer failed to ensure the use of specific energy control procedures.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $5801

1910.219 D01

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4144.00 · Current $2000.00 Reduced
29 CFR  1910.219(d)(1):Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes.  On or about September 8, 2022, employees engaged in performing pumpjack repair operations were exposed to caught in hazards from an unguarded pulley.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $4144

1910.219 E03 I

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section.   On or about September 8, 2022, employees engaged in performing pumpjack repair operations were exposed to caught in hazards from an unguarded belt.