MAYWOOD, NJ —
OSHA Inspection: WELL-BUILT CARPENTRY & BUILDERS INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WELL-BUILT CARPENTRY & BUILDERS INC in 708 MAYWOOD AVE, MAYWOOD, NJ 07607 (NAICS 238130). OSHA activity number 346209844.
Where did this inspection happen?
- Establishment
- WELL-BUILT CARPENTRY & BUILDERS INC
- Site address
- 708 MAYWOOD AVE
- City
- MAYWOOD
- State
- NJ
- ZIP
- 07607
- Mailing
- 307 MAIN STREET, LODI, NJ 07644
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $4688.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system. a) sub- roof: An employee was expose to a fall hazard of approximately 14 feet to the ground below while standing and moving an extension ladder without the use of personal fall arrest system, on or about 9/8/22.
Recent events (3)
- — J (S) $3500
- — C (S) $4688
- — Z (S) $4688
1926.502 D
- Issued
- Penalty
- Initial $4688.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.502(d): "Personal fall arrest systems." Personal fall arrest systems and their use shall comply with the provisions set forth below. Effective January 1, 1998, body belts are not acceptable as part of a personal fall arrest system. Note: The use of a body belt in a positioning device system is acceptable and is regulated under paragraph (e) of this section. a) Roof: An employee was using a rope tie around his waist as part of the Personal fall arrest systems, and did not comply with the provisions as required, on or about 9-8-22. -
Recent events (3)
- — J (S) $0
- — C (S) $4688
- — Z (S) $4688
1926.502 D06 I
- Issued
- Penalty
- Initial $4688.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.502(d)(6)(i):A snaphook not of the design type was engaged (i) directly to webbing, rope or wire rope; (ii) to each other; (iii) to a Dee-ring to which another snaphook or other connector is attached; (iv) to a horizontal lifeline; or (v) to any object which is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself: a) Roof: An employee was using a personal fall arrest system that the vertical life line snaphook was directly engaged to the rope, on or about 9/8/22
Recent events (3)
- — J (S) $0
- — C (S) $4688
- — Z (S) $4688
1926.502 D11
- Issued
- Penalty
- Initial $4688.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.502(d)(11):Lifelines were not protected against being cut or abraded: a) Roof chimney: An employee was utilizing a vertical lifeline that was in direct contact with the edge chimney without protection from being cut or abraded, on or about 9/8/22.
Recent events (3)
- — J (S) $0
- — C (S) $4688
- — Z (S) $4688
1926.1053 B01
- Issued
- Penalty
- Initial $4688.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Roof: Well Build Carpentry & Builder Inc does not ensure that where portable ladders that were used to access an upper landing surface, the ladder side rails extend at least 3 feet above the upper landing surface that was being accessed. This violation was most recently observed, on or about 9/8/22
Recent events (3)
- — J (S) $3500
- — C (S) $4688
- — Z (S) $4688
1926.1053 B12
- Issued
- Penalty
- Initial $4688.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive side rails: a) building exterior front: Well-Built Carpentry & Builders Inc, does not ensure that the employee or the ladder could contact exposed energized electrical equipment had non conductive side rails. This violation was most recently observed, on or about 9/8/22
Recent events (3)
- — J (S) $0
- — C (S) $4688
- — Z (S) $4688
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346209844.