Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DARREN DAVIS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DARREN DAVIS in 6485 SPRING RUN ROAD, WESTERVILLE, OH 43082 (NAICS 238160). OSHA activity number 346216997.

Watch Darren Davis — free Get an email when a new federal OSHA severe-injury report for Darren Davis is published. One employer, no account, unsubscribe in one click.
Establishment
DARREN DAVIS
Site address
6485 SPRING RUN ROAD
City
WESTERVILLE
State
OH
ZIP
43082
Mailing
2500 HARRISBURG PIKE, GROVE CITY, OH 43123
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

4 citations on file for this inspection.

1926.20 B01

Serious Gravity 5 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $3108.00 · Current $3108.00
29 CFR  1926.20(b)(1):It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.  a)  Darren Davis DBA The Roof Wrangler located at 6485Spring Run Road, WESTERVILLE, OH 43082: On and preceding August 13, 2022, the employer did not initiate and maintain safety and health programs for employees removing/installing roofing shingles, thereby exposing employees to the hazards associated with performing roofing work.
Recent events (1)
  • — Z (S) $3108

1926.102 A01

Serious Gravity 5 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $3108.00 · Current $3108.00
29 CFR  1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.   a)  Darren Davis DBA The Roof Wrangler located at 6485Spring Run Road, WESTERVILLE, OH 43082: On and preceding August 13, 2022,  the employer did not ensure that roofers installing shingles using pneumatic nail guns wore appropriate eye protection thereby exposing them to struck-by hazards to the eyes.
Recent events (1)
  • — Z (S) $3108

1926.501 B13

Serious Gravity 10 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $4351.00 · Current $4351.00
29 CFR  1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.   a)  Darren Davis DBA The Roof Wrangler located at 6485Spring Run Road, WESTERVILLE, OH 43082: On and preceding August 13, 2022,  the employer did not ensure that roofers installing shingles and other materials on a roof of a multi-story residential home at heights varying in height from 10 to 26 feet wore appropriate fall protection thereby exposing the employees to falls up to 26 feet.
Recent events (1)
  • — Z (S) $4351

1926.1053 B01

Serious Gravity 5 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $2486.00 · Current $2486.00
29 CFR  1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.   a)  Darren Davis DBA The Roof Wrangler located at 6485Spring Run Road, WESTERVILLE, OH 43082: On and preceding August 13, 2022,  the employer did not ensure that an extension ladder used for access to the roof of a multi-story residential house had the side rails extending at least 3 feet beyond the upper landing nor was the ladder secured the top with a grasping device provided. The following condition exposed employees to falls up to 10 feet.
Recent events (1)
  • — Z (S) $2486