BUFFALO GROVE, IL —
OSHA Inspection: PPC FLEXIBLE PACKAGING, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PPC FLEXIBLE PACKAGING, LLC in 1111 BUSCH PARKWAY, BUFFALO GROVE, IL 60089 (NAICS 323111). OSHA activity number 346233869.
Where did this inspection happen?
- Establishment
- PPC FLEXIBLE PACKAGING, LLC
- Site address
- 1111 BUSCH PARKWAY
- City
- BUFFALO GROVE
- State
- IL
- ZIP
- 60089
- Mailing
- 1111 BUSCH PARKWAY, BUFFALO GROVE, IL 60089
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 118
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $15469.00 · Current $9000.00 Reduced
General-duty citation text
29 CFR 1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a) Production Area - On or about September 15, 2022, an employee was exposed to machine hazards associated with rotating parts during wiping down and cleaning of the Pan Deck #5, on the Bielloni Tonema Telia Gearless Press Machine. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)], and verification of isolation [(d)(6)], were not implemented to protect the employee from machine servicing hazards. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $9000
- — Z (S) $15469
1910.147 F03 II
- Issued
- Abate by
- Penalty
- Initial $15469.00 · Current $9000.00 Reduced
General-duty citation text
29 CFR 1910.147(f)(3)(ii): Group lockout or tagout devices were not used in accordance with procedures required by 29 CFR 1910.147(c)(4): a) Production Area - On or about September 15, 2022, a group lockout procedure was not utilized by employees conducting servicing and maintenance work such as cleaning the pans on the Bielloni Tonema Telia Gearless Press Machine. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $9000
- — Z (S) $15469
More inspections at PPC FLEXIBLE PACKAGING, LLC
PAYSON, UT—2024-11-06 00:00:00
PPC FLEXIBLE PACKAGING, LLC
BUFFALO GROVE, IL—2024-04-04 00:00:00
PPC FLEXIBLE PACKAGING, LLC
ROME, GA—2023-07-25 00:00:00
PPC FLEXIBLE PACKAGING, LLC
BUFFALO GROVE, IL—2022-11-08 00:00:00
PPC FLEXIBLE PACKAGING, LLC
BUFFALO GROVE, IL—2019-01-04 00:00:00
PPC FLEXIBLE PACKAGING, LLC
View PPC FLEXIBLE PACKAGING, LLC's full OSHA safety record →
More inspections in this industry (NAICS 323111)
MUSKEGON, MI—2026-07-08
GRAPHICS HOUSE PUBLISHING, INC
WARMINSTER, PA—2026-07-02
INNOTECH LASER
HERMITAGE, PA—2026-07-01
CCL CONTAINER, INC.
GREEN BAY, WI—2026-06-30
CHARTER NEXT GENERATION, INC.
LEHI, UT—2026-06-25
FIVE INC.
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346233869.