JEFFERSON, WI —
OSHA Inspection: JOE MASOT ROOFING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOE MASOT ROOFING INC. in 237 WILSON AVE, JEFFERSON, WI 53549 (NAICS 238160). OSHA activity number 346235450.
Where did this inspection happen?
- Establishment
- JOE MASOT ROOFING INC.
- Site address
- 237 WILSON AVE
- City
- JEFFERSON
- State
- WI
- ZIP
- 53549
- Mailing
- 914 LANDON AVE, WINTHROP HARBOR, IL 60096
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1903.19 D01
- Issued
- Abate by
- Penalty
- Initial $376.00 · Current $376.00
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. The employer failed to submit certification and documentation of abatement within 10 days of the abatement date for Citation 1 Items 1, 2, 3 and 4. ABATEMENT CERTIFICATION AND DOCUMENTATION IS REQUIRED FOR THIS ITEM
Recent events (1)
- — Z (O) $376
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $4351.00
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. On or about September 19, 2022, employees reinstalling shingles on the roof of a single-story residential building during reroofing, at a height greater than six feet, were not protected from falls to the lower level.
Recent events (1)
- — Z (S) $4351
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $2486.00 · Current $2486.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. On or about September 19, 2022, the employer did not ensure employees exposed to potential fall hazards had been trained to recognize and minimize the fall hazards associated with their work in that all employees were working from heights greater than six feet without fall protection.
Recent events (1)
- — Z (S) $2486
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $4351.00
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about September 19, 2022, employees reinstalling shingles on the roof of a multi-story residential building during reroofing and did not have the ladder used for accessing the roof at least 3 feet above the landing surface.
Recent events (1)
- — Z (S) $4351
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $1865.00 · Current $1865.00
General-duty citation text
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. On or about September 19, 2022, employees shingling a multi-level residential roof while using pneumatic nail machines were doing so without the use of eye protection exposing the employees to eye or face hazards from flying particles.
Recent events (1)
- — Z (S) $1865
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source